Table 8: Trouble indications
Trouble
Trouble
Indicator
Indication
Digit
Green LEDs
N/A
alternating
E
THERNET
The programming sections described in this document can be viewed at the keypad LCD. To start
programming enter: [*][8][installer code] [851] [section number], where section number is the 3
digit section number referenced in this section. The programming worksheets at the end of this
document can be used to record the new values when programming changes have been made from
the default values.
Programming sections are accessed through the panel keypad. Installers may set/review/record
programming options at the panel keypad.

System Options

[001] Ethernet IP Address
Default (000.000.000.000)
Enter the IP address of the communicator. Ensure that the IP address is unique to the communica-
tor on the local network. Format is 4 fields, each field is a 3 digit decimal number. Valid range:
000-255. If an IP address is programmed in this section, the unit will operate with static IP (DHCP
disabled). Sections [002] and [003] must also be programmed when using static IP addresses.
NOTE: Default for this section is Dynamic Host Configuration Protocol (DHCP) enabled. When
enabled, the DHCP server will set values for: IP address [001], subnet mask [002], and
gateway [003]. Programming an IP address in this section will disable DHCP (Static IP).
[002] Ethernet IP Subnet Mask
Default (255.255.255.000)
Enter the Ethernet IP subnet mask of the communicator. Format is 4 fields, each field is 3 digits.
Valid range: 000-255.
NOTE: If DHCP is enabled, the DHCP server will assign the subnet mask for this section and the
programmed value will be ignored.
[003] Ethernet Gateway IP Address
Default (000.000.000.000)
Enter the Ethernet gateway IP address of the communicator. The gateway IP address is required
when a router is used on the local network to reach the destination IP address specified in section
[001]. Format is 4 fields, each field is a 3 digit decimal number. Valid range: 000-255.
NOTE: If DHCP is enabled, the DHCP server will assign the gateway IP address for this section
and the programmed value will be ignored.
[004] Receiver Supervision Interval
Default (0087/135)
When receiver supervision is enabled (ON) in section [005] toggle option [3], the unit sends heart-
beats to Ethernet receiver 1 or cellular receiver 1 to test the communications path. Use this section
to set the interval time (in seconds) when heartbeats will be sent to the receivers. Valid range
000A-FFFF seconds. If the programmed value is less than (000A/10) seconds, supervision is dis-
abled.
• Receiver Window: This is the supervision timeout that must be configured at the central sta-
tion receiver.
• Recommended Values: This is the recommended heartbeat interval that should be pro-
grammed into the communicator.
HSPA(3G) Alarm Communicator Installation Manual
Possible
Causes
Radio Reset or
• If this status persists and the yellow LED shows 5 flashes, confirm that
Radio Initializa-
the SIM card is active.
tion
/C
ELLULAR
Trouble Possible Solution
P
ROGRAMMING
19
O
PTIONS