[215] Cellular Receiver 2 APN
Default ( )
The APN determines the cellular network that the communicator will connect to. This information
is available from your network carrier. Program this section with up to 32 ASCII characters.
NOTE: When a SIM card with a custom APN is used, the unit will not have access to the Internet.
DLS and remote flash can still be done if section [221] is programmed with a valid public
APN.
[216] Cellular Receiver 2 Domain Name
Default ( )
Enter the cellular receiver 2 Domain Name with up to 32 ASCII characters.

Cellular Options

[221] Cellular Public Access Point Name
Default ( )
When the communicator is operating on a private APN, use this section to select a public APN for
DLS and remote firmware update. This information is available from your network carrier. The
APN identifies the public cellular network that the communicator will connect to.
[222] Cellular Login User Name
Default ( )
Some network carriers require you to provide login credentials when connecting to an APN. Pro-
gram your login user name in this section. Format is up to 32 ASCII characters.
[223] Cellular Login Password
Default ( )
Some network carriers require you to provide login credentials when connecting to an APN. Pro-
gram your login Password in this Section. Format is up to 32 ASCII characters.
[224] Cellular Test Transmission Time of Day
Default (9999)
Enter a 4 digit value using the 24-hour clock format (HHMM) to set the test transmission time of
day. Valid range: 00-23 for the hours (HH) and 00-59 for the minutes (MM).
NOTE: To disable the test transmission time of day enter 9999 or FFFF in this section.
The internal date and time will be automatically programmed by the primary receiver only.
[225] Cellular Test Transmission Cycle
Default (000000)
This value represents the interval in between test transmissions in minutes. Valid range: 000000 -
999999 minutes. Once the unit has sent the initial periodic test transmission, all future test trans-
missions will be offset by the programmed number of minutes. See sections [026] - [029].
Table 14: Cellular Test Transmission Interval
Test Transmission Interval
Programmed Minutes
NOTE: Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes
will disable test transmission.
[226] Cellular Trouble Delay
Default (0A)
This option is used to program the delay, in minutes, for reporting a cellular trouble delay. Valid
entries are 00 - FF. (e.g., for a 10 minute cellular trouble delay enter: 0A). There is no reporting
delay if value is programmed as 00.

SMS Event Notification/Command and Control Options

When an event is triggered by the panel and SMS notification is ON in section [301] toggle option
[1], an SMS message is created and sent to the SMS telephone numbers programmed in sections
[311]-[342] for event types specified in sections [343]-[374] if toggle [7] is ON. The system will
make one attempt to send the SMS message to each of the programed telephone numbers, starting
HSPA(3G) Alarm Communicator Installation Manual
Daily
001440
Weekly
Monthly
010080
043200