2.4.7.2 The "Valid From" and "Valid To" Settings
ValidFrom and ValidTo fields specify the day(s) a security code is valid, and, optionally the time, in
24:00 format.
The Day of the week can be Mon, Tue, Wed, Thu, Fri, Sat, Sun, or one of the special identifiers: All,
Wnd, and Wdy.
Wdy indicates weekdays (Monday-Friday).
Wnd indicates weekends (Saturday-Sunday).
All allows entrance at all times.
A valid string consists of a day of the week or a special identifier, plus an optional time, except if
using All, which will not use a time.
Some examples:
<ValidFrom0>Mon9:00</ValidFrom0>
<ValidTo0>Fri17:00</ValidTo0> monday through friday 9am to 5pm
<ValidTo0>All</ValidTo0>
<ValidTo0>All12:00</ValidTo0> every day till 12:00
<ValidTo0>Mon12:00</ValidTo0> times are inclusive - this code is only valid on monday at 12:00
<ValidFrom0>Wdy9:00</ValidFrom0>
<ValidTo0>Wdy17:00</ValidTo0> Weekdays from 9am to 5pm
Note
Note
Operations Guide
<ValidFrom0>All</ValidFrom0>
<ValidFrom0>All</ValidFrom0>
<ValidFrom0>Mon12:00</ValidFrom0>
The identifiers in to and from must match (for example, named day/named day, Wdy/
Wdy, Wnd/Wnd, All/All).
The device must set time with an
NTP server is not used, all
931562B
Installing the SIP Outdoor Intercom with Keypad
all day every day
NTP Server
(see the
Valid From
and
Valid To
Intercom Setup
Device Configuration
fields must be set to All.