Drive To Absolute - Drva Instruction; Instruction Format - Mitsubishi FX3G Series User Manual

Melsec-f, positioning control edition, main unit/sink output/source output, line driver output
Hide thumbs Also See for FX3G Series:
Table of Contents

Advertisement

FX
/FX
/FX
PLC User's Manual - Positioning Control Edition
3G
3U
3UC
Built-in Positioning Functions
8.3

Drive To Absolute - DRVA Instruction

8.3.1

Instruction Format

1. Instruction format
FNC 159
D
DRVA
DRIVE TO
ABSOLUTE
Command
input
FNC 159
DRVA
2. Data setting
Operand type
S
1
S
2
D
1
D
2
*1.
Setting range : -32,768 to +32,767 for 16-bit operation
*2.
Setting range : 10 to 32,767 Hz for 16-bit operation
3. Devices
Operand
type
X Y M T C S D .b KnX KnY KnM KnS T C D R U \G
S
1
S
2
D
1
1
D
2
2
1 : Specify Y000, Y001, or Y002
*3
Y003
from a high-speed output special adapter
*1.
Y002 is not available in 14-point and 24-point type FX
*2.
High-speed input/output special adapters can be connected only to the FX
*3.
To use Y002 and Y003 with a high-speed output special adapter, connect a second high-speed output
special adapter.
Caution:
• To use an FX
adapter. Differential line drive type outputs will be used for the outputs of the high-speed output special
adapter.
B - 116
16-bit
Instruction
instruction
symbol
DRVA
9 steps
-
S
S
D
1
2
Specifies the number of output pulses (absolute address).
Specifies the output pulse frequency.
Specifies the pulse output number.
Specifies the rotation direction signal output destination device number.
: -999,999 to +999,999 for 32-bit operation
For 32-bit operation, however, the setting range is as shown in the following table.
Pulse output destination
FX
PLC
3U
FX
/FX
/FX
PLC Main unit (transistor output)
3G
3U
3UC
Bit device
System user
Digit designation
3
*1
transistor output from the main unit, or specify Y000, Y001, Y002
Series main unit of relay output type, be sure to connect a high-speed output special
3U
8 1-Speed Positioning - DRVI/DRVA Instruction
Execution condition
Continuous
execution
type
D
1
2
Description
*2
High-speed output special adapter
Word device
System
Special
user
unit
*2
.
PLC.
3G
8.3 Drive To Absolute - DRVA Instruction
32-bit
Instruction
Execution condition
instruction
symbol
DDRVA
17 steps
-
*1
Setting range
10 to 200,000(Hz)
10 to 100,000(Hz)
Real
Con-
Index
num-
stant
ber
V Z Modify K H
4
4
PLC.
3U
Continuous
execution
type
Data type
BIN16/32-bit
Bit
Others
Char-
acter
Pointer
string
E
" "
P
*3
, or

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3u seriesFx3uc seriesFx3u-2hsy-adp

Table of Contents