FX
/FX
/FX
PLC User's Manual - Positioning Control Edition
3G
3U
3UC
Built-in Positioning Functions
2
Set the memory capacity.
Click on the "Memory capacity" tab, and then click on the "Positioning Instruction Setting" check
box to enter a check in the box.
Enter a check.
Setting item
Memory capacity
Comment capacity
File register capacity
Program capacity
Special Function Memory
capacity
Special Function Block
*2
Settings
Positioning Instruction
settings
*1.
The initial value is 8000 steps for GX Developer below Ver.8.22Y.
The initial value is "8000 steps" in the
*2.
Only available for
B - 144
*1
Set the capacity of the program memory. Initial value: 16000
Set the capacity for the comments to be stored in the PLC. Initial
value: 0
Device comment: 50 points/block (500 steps)
Set the capacity for the file registers. Initial value: 0
File registers: 500 points/block (500 steps)
Displays the number of steps that can be used for the sequence
program.
Set whether the special unit initial data setting function and the
positioning data setting function should be enabled.
Enter a check in the check box to enable the special function unit/
block initial data setting function. Use the "I/O Assignment Setting"
tab to set the initial value of a special unit.
Enter a check in the check box to enable the TBL (FNC152)
instruction setting function. Use the "Positioning Data Setting" tab to
set the positioning data.
and
PLCs.
FX
FX
3U
3UC
11 Batch Data Positioning Mode (TBL Instruction)
Description of setting
PLC.
FX
3G
11.4 Positioning Parameter Setting
Setting range
*1
Refer to the
programming
manual.
-
-
-