Front Panel Ports; Table 3-3: Sfp Uplink Port Pinout - Kontron CP6924-1 User Manual

Standard fabric 6u compactpci gigabit ethernet switch
Table of Contents

Advertisement

Ethernet Link Port Status LEDs (24 fabric interface LEDs for status indication)
Off
link down
On
link up but no activity
Blinking
link up and activity
CPU 10/100/1000Base-T Management port LEDs
Link/Activity: green LED
Off
link down
On
link up but no activity
Blinking
link up and activity
Speed: amber/green LED
Off
10Base-T
On (amber)
100Base-Tx
On (green)
1000Base-T
Onboard Debug LEDs (CPLD active LED)
Off
CPLD is out of reset, but not all power rails are ready
On
CPLD is in reset
Blinking
CPLD is out of reset
CPLD Health LED
The CPLD Health LED indicates that all voltages are within their specified range and the CPLD is out of reset.
3.4.4

Front Panel Ports

3.4.4.1
SFP/SFP+ Uplink Ports
The SFPs uplink ports are according the Small Form-factor Pluggable (SFP) Transceiver MultiSource Agreement (MSA), Sept.
14th, 2000. The SFP connectors have the following pin assignment:
Table 3-3:
SFP Uplink Port Pinout
PIN
Signal
1
GND
2
TX_FAULT
3
TX_DIS
4
MODDEF2
5
MODDEF1
6
MODDEF0
7
R_SEL
8
LOS
1)
9
GND
10
GND
11
GND
12
RD-
13
RD+
14
GND
31
1)
1)
1)