Boot Fail *(Sensor Type 1Eh)
Table 4-16:
Boot Fail (Sensor Type 1Eh) Reading
Offset
Request data
1
1
2
3
Response data
4
5
Table 4-17:
Boot Fail (Sensor Type 1Eh) Event Message
Offset
1
2
3
4
Request data
5
6
7
Response data
1
73
Sensor Number
Completion Code
Sensor Reading
00h – ignore on read
Standard IPMI Byte. (See "Get Sensor Reading in the IPMI Specification)
[7:4] – reserved, ignore on read
[3] – 1b = permanent boot failure, no more images to try
[2] – 1b = activation of backup image, boot failure detected
[1] – 1b = network boot error
[0] – 1b = local boot error while executing from flash
80h – ignore on read
Event Message Rev
04h
Sensor Type
1Eh – Boot Error *
Sensor Number
[7] – Event Direction
1b = Deassertion
0b = Assertion
[6-0] – Event Type
6Fh = sensor specific
Event Data 1
[7:4] – 80h = OEM data in Event Data 2 and no data in Event Data 3
[3:0] – Offset
00h = local boot error while executing from flash
01h = network boot error
02h = activation of backup image, boot failure detected
03h = permanent boot failure, no more images to try
All other values are reserved.
Event Data 2
01h = failed image is image 1
00h = failed image is image 0
Event Data 3
FFh = not specified
Completion Code
CP6924-1 User Guide
www.kontron.com