Technical Specification; Power Requirements; Mechanics; Temperature - Kontron CP6924-1 User Manual

Standard fabric 6u compactpci gigabit ethernet switch
Table of Contents

Advertisement

1.2

Technical Specification

1.2.1

Power Requirements

Operating voltages are 5.0 Volt and 3.3 Volt.
The maximum power consumption is less than 50W.
1.2.2

Mechanics

Compliant to PICMG® 2.0 6U/4HP (233.35 mm x 160 mm).
Weight:
CP6924-1-RA-OC and CP6924-1-SA-OC-V: 720g
CP6024-1-RC: 1170g
The CP6924-1-RA-OC and CP6924-1-SA-OC-V use a front panel. The CP6924-1-RC does not need a front panel.
1.2.3

Temperature

Compliant to IEC 60068-2-1 and IEC 60068-2-2.
CP6924-1-RA-OC
Operation from -40° C to +85° C inlet air temperature
CP6924-1-RC
Operation from -40° C to +85° C wedge lock temperature
CP6924-1-SA-OC-V
Operation from 0° C to +60° C inlet air temperature
Required average inlet airflow should be around 400LFM (2 m/s) for the maximum cooling. Other thermal limitations may
apply and are the responsibility of the system integrator.
Storage temperature range is -50° C to +105° C for all variants.
1.2.4

Humidity

The boards are designed to meet the standard IEC 60068-2-78 operating 93% at 40°C (non-condensing).
1.2.5

Altitude

The boards are designed to meet the following requirements:
Operating: 4000m (13123 ft). Check for onboard peripherals if applicable
Non-Operating: 15000 m (49212 ft)
1.2.6

Vibration

The CP6924-1-SA-OC-V board is designed to meet the requirements according ANSI/Vita 47 V2:
Class V2 plug-in units shall withstand vibration as defined below for 1 hour per axis:
5 Hz to 100 Hz PSD increasing at 3 dB/octave
100 Hz to 1000 Hz PSD = 0.04 g2/Hz
1000 Hz to 2000 Hz PSD decreasing at 6 dB/octave
The CP6924-1-RA-OC board is designed to meet the requirements according EN60068-2-6:
10 Hz to 300 Hz, 2g acceleration
1 octave/min
10 cycles/axis, 3 directions [x, y, z]
14
CP6924-1 User Guide
www.kontron.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp6924-1-ra-ocCp6924-1-rcCp6924-1-sa-oc-vCp6924