MMC Reboot (Type 24h)
Table 4-10:
MMC Reboot (Type 24h) Reading
Offset
Request data
1
1
2
3
Response data
4
5
Table 4-11:
MMC Reboot (Type 24h) Event Message
Offset
1
2
3
4
Request data
5
6
7
Response data
1
SDR Configuration
Assertion Event Mask
Deassertion Event Mask
70
Sensor Number
Completion Code
Sensor Reading
00h – ignore on read
Standard IPMI Byte. (See "Get Sensor Reading in the IPMI Specification)
[7:2] – Reserved, read as zero
[1] – 1b = MMC in Reset
[0] – 1b = MMC out of Reset
80h – Ignore on read
Event Message Rev
04h
Sensor Type
24h – Platform Alert
Sensor Number
[7] – Event Direction
1b = Deassertion
0b = Assertion
[6-0] – Event Type
03h = digital discrete
Event Data 1
[7:4] – 0h = no data in Event Data 2 and 3
[3:0] – Offset
00h = MMC out of Reset
01h = MMC in Reset
All other values are reserved.
Event Data 2
FFh = not specified
Event Data 3
FFh = not specified
Completion Code
Value
02h
Offset 1 can generate an assertion event
00h
Sensor cannot generate deassertion events
CP6924-1 User Guide
Description