Table 4-12: Mmc Fwup (Type C7H) Reading; Table 4-13: Mmc Fwup (Type C7H) Event Message - Kontron CP6924-1 User Manual

Standard fabric 6u compactpci gigabit ethernet switch
Table of Contents

Advertisement

MMC FwUp (Type C7h)
Table 4-12:
MMC FwUp (Type C7h) Reading
Offset
Request data
1
1
2
Response data
3
4
5
Table 4-13:
MMC FwUp (Type C7h) Event Message
Offset
1
2
3
4
Request data
5
6
7
Response data
1
SDR Configuration
Assertion Event Mask
Deassertion Event Mask
71
Sensor Number
Completion Code
Sensor Reading
00h = first boot after upgrade
01h = first boot after rollback
All other values are reserved.
Standard IPMI Byte. (See "Get Sensor Reading in the IPMI Specification)
00h - ignore on read
80h – ignore on read
Event Message Rev
04h
Sensor Type
C7h – OEM Firmware Upgrade
Sensor Number
[7] – Event Direction
1b = Deassertion
0b = Assertion
[6-0] – Event Type
6Fh = sensor specific
Event Data 1
[7:4] – 0h = no data in Event Data 2 and 3
[3:0] – Offset
00h = first boot after upgrade
01h = first boot after rollback
All other values are reserved.
Event Data 2
FFh = not specified
Event Data 3
FFh = not specified
Completion Code
Value
01h
Offset 0 can generate an assertion event
00h
Sensor cannot generate deassertion events