The CP6924-1-RC board is designed to meet the requirements according ANSI/Vita 47 V3:
Class V3 plug-in units shall withstand vibration as defined below for 1 hour per axis:
5 Hz to 100 Hz PSD increasing at 3 dB/octave
100 Hz to 1000 Hz PSD = 0.1 g2/Hz
1000 Hz to 2000 Hz PSD decreasing at 6 dB/octave
Note...
If the CP6924-1 board is used in heavy shock and vibration environment, the hole system
must withstand these requirements. This means the chassis, backplane and guiderails
should be designed for harsh environment. Guide rails with wedge locks are recommend.
The backplane has to be stiffened to avoid connector micro movement. It is also recom-
mended to use connectors which are designed for a rugged environment.
1.2.7

Shock

The CP6924-1-RC board is designed to meet the requirements according VITA 47: 40g.
The plug-in unit shall withstand exposure to either 40g, 11 millisecond, half-sine or 40g, 11 millisecond, terminal saw
tooth shock pulses in all three axes. If verification is accomplished by test, then testing shall be accomplished in accor-
dance with MIL-STD-810, Method 516, Procedure I.
The CP6924-1-RA-OC board is designed to meet the VITA 47 standard:
Peak Acceleration: 20 g, Shock Duration: 11 ms, Recovery Time: 5 s, Shock Count: 3/direction,
6 directions
The CP6924-1-SA-OC-V board is designed to meet the requirements of the following standards:
DIN/IEC 60068-2-27
Peak Acceleration: 30 g, Shock Duration: 9 ms half sine, Recovery Time: 5 s, Shock Count: 3/direction,
6 directions
DIN/IEC 60068-2-27
Peak Acceleration: 15 g, Shock Duration: 11 ms half sine, Shock Counts: 500/direction, Recovery Time: 1 s
1.2.8

Safety

The boards are designed to meet or meets the following requirements:
UL 60950-1, 2nd Edition (US and Canada)
EN 60950-1, (Europe)
The boards are designed to meet the following flammability requirement (as specified in Telcordia GR-63-CORE):
UL 94V-0/1 with Oxygen index of 28% or greater material
1.2.9

Electromagnetic Compatibility

The boards are designed to meet or exceed class B limit of the following specifications/requirements (assuming an ade-
quate system/chassis):
FCC 47 CFR Part 15, Subpart B (USA)
EN55022 (Europe)
EN55024 (Europe)