Board Sensors

The Management Controller includes many sensors for voltage or temperature monitoring and various others for pass/fail
type signal monitoring.
Every sensor is associated with a Sensor Data Record (SDR). Sensor Data Records contain information about the sensors
identification such as sensor type, sensor name, sensor unit. SDRs also contain the configuration of a specific sensor such
as thresholds, hysteresis, event generation capabilities, etc. that specify the sensor's behavior. Some fields of the sensor
SDR are configurable through IPMI v1.5 command and are set to a built-in initial value.
Module sensors that have been implemented are listed in the sensor list in Table 4-7.
4.4.2.1
Sensor List
Please note that the IPMI tool 'ipmitool' displays for command 'ipmitool sdr list' the contents of the sensor data record
repository (SDRR) of the whole rack if the SDRR is generated. The generation of the SDRR has always to be done new after
adding or subtracting any board to or from the rack.
65
Pass Code 0: ~'K'
Pass Code 1: ~'o'
Pass Code 2: ~'n'
Pass Code 3: ~'t'
Completion Code
LUN
NetFn
3
OEM = 3Eh
Data Field
CP6924-1 User Guide
CMD