Software Loading Procedures - Taylor C832 Service Manual

Mcdonald's intelligap grills
Table of Contents

Advertisement

Software Loading Procedures

IMPORTANT: After loading new software, the
gap, volume, and temperature settings will be at
the default factory settings.
Step 1
Record the present settings for system setup
and key menu items.
a. Turn the Fan Interlock Switch to the ON position.
b. While "OFF" is displayed, press the
and enter the Service Menu passcode.
c. Press the
key until "SYSTEM SETUP" is
displayed.
d. Press the
key. The display will read
"PROBE CALIBRATION/TOP BACK."
e. Record the offset.
f. Press the
key to display "PROBE
CALIBRATION/TOP FRONT."
g. Record the offsets.
140922
Controls and Systems
h. Repeat until all offsets are recorded and then
press the
i. Press the
"GAP CALIBRATION."
j. Document the settings for the right side.
k. Press the
sides. Document all settings.
key
Step 2
Download the new software.
a. Place the Fan Interlock Switch in the OFF
position.
b. Remove the screw on the right and left edge of
the lower front panel to allow the panel to swing
down.
c. Loosen one screw on the back of the control to
allow the access door to swing open.
d. Insert the program module into the receptacle
located under the door. (See Figure 41.)
e. Swing the lower front panel up to view the
display.
Figure 41
50
key.
key until the screen displays
key to go to the front and left
McDonald's Intelligap Grills

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C834C842C844C845C836C835 ... Show all

Table of Contents