Model C845 Specifications
See the data label for exact specifications.
Electrical
Standard is 208/60/3 phase.
Two dedicated electrical connections are required;
one, three phase and one interlock/control single
phase. See the electrical chart for the proper
electrical requirements. Manufactured to be
permanently connected. Consult your KES or local
Taylor distributor for cord and receptacle
specifications as local codes allow.
Electrical
Total
Total
Amp
KW
208/60/3
22
7.8
200/50/60/3
23
7.8
220/380/60/3
12
7.8
220/50/60/3
20
7.8
400/50/3n~4w
11
7.8
McDonald's Intelligap Grills
Interlock/
Interlock
Control
Fuse
Voltage
Size
120/60/1
10A
100/50/60/1
10A
230/60/1
10A
220/60/1
10A
230/50/1
10A
Figure 8
13
Gas
Three ceramic infrared burners: 25,000 BTUH each.
Manifold pressure: 3.5" w.c. natural, 10.5" w.c.
propane.
Dimensions
Width: 38" (965 mm)
Depth: 38-1/2" (978 mm)
Height : 50-1/2 to 55-1/2" (1283 to 1410 mm)
Cooking Surface Height: 29 to 34" (737 to 864 mm)
Floor Clearance: 3-3/4 to 8-3/4"
(96 to 223 mm) (Casters may be adjusted.)
Approximate Weight
Net: 923 lbs. (418.7 kgs.)
Crated: 1032 lbs. (468.1 kgs.)
Volume
52.6 cu. ft. (1.49 cu. m.)
150520
Introduction