Section 6: Operating Procedures; Display Screen Functions - Taylor L850 Operator's Manual

Active compression grills
Table of Contents

Advertisement

Section 6

Display Screen Functions

ON Key—Activates and deactivates the grill con-
trol.
Home Key—Takes you to the Main Screen.
Information Key—Displays the current status of
the machine (examples: temperatures of upper
platens and lower cook surfaces, date when the
last cleaning was performed, and date when the
last product integrity was performed.)
Alert Key—Displays the recent faults and
events. Highest level of concern.
Power Key—Takes you to the screen to turn the
grill heaters ON or OFF.
AM/PM Key—Toggle between breakfast and
lunch menu items.
Menu Key—Displays list of available actions in
the grill.
Help Key—Content details of current screen.
Future development.
Operating Procedures
Operating Procedures
Probe Calibration
Thermocouple probes are located on the front and rear of
the lower grill plates and upper platens. The
measurements should be taken from front to back and
left to right on all model grills.
Figure 6-1 identifies the probe locations for the Model
L858 and L852 cook grill.
Note:
Drill points off-centered from grill row markings
indicate probe locations.
Model L850, L852, L858 Series
Figure 6-1
6
6-1