Taylor C832 Service Manual page 47

Mcdonald's intelligap grills
Table of Contents

Advertisement

Gap Calibration
Step 1
From the SYSTEM SET UP menu, press the
key until the screen displays "GAP CALIBRATION."
(Note: The factory default setting is .015 for all three
motors.)
GAP CALIBRATION
+.000
+.000
Step 2
Using the 10:1 gapping rod, check the four corners
of the platen.
Step 3
Use the
keys to adjust the gaps. If the
gaps are too low, use the
platen. If the gaps are too high, use the
lower the platen.
Note: Gap changes will not be recognized until the
Auto-Level Sequence has been completed.
Step 4
Pay close attention to the display. The motors are in
sequence as follows: RIGHT - FRONT - LEFT.
Press the
keys to move to the other
motors.
Step 5
After changing the gap settings, press the
once and then press the
Step 6
Press the RAISE button to raise the platen.
McDonald's Intelligap Grills
+.000
key to raise the
key to
key
key.
41
Step 7
Press the
key twice and then press the
key to Auto-Level the platen. (See Auto Leveling on
page 23.)
IMPORTANT! Always Auto-Level the platen
when changing the gaps. If the platen is not
re-leveled, the offsets will show the changes, but the
motors will still have the previous settings.
Step 8
Place the platen into STANDBY and check the gaps.
Repeat these steps, if needed.
Auto Threshold
Auto Threshold is the minimum gap setting that the
platen will recognize a product. Anything below
0.020 will not be recognized.
IMPORTANT! DO NOT adjust the Auto Threshold
gap setting.
Step 1
From the SYSTEM SET UP menu, press the
key until the screen displays "AUTO THRESHOLD".
AUTO THRESHOLD
0.020
Step 2
Press the
key to return to the AM/PM Mode.
Step 3
Press the
key to exit the programming mode,
or wait for the display to time out after 3-5 seconds.
Controls and Systems

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C834C842C844C845C836C835 ... Show all