Install Standoff S; Install 6-5/8" X 4" Vent Adapter (If Required); Install Heatshift Take-Off Collars (Required); Prepare Appliance For Wiring - Valor LX2 Series Installation & Owner's Manual

Direct vent zero clearance corner gas fireplaces
Hide thumbs Also See for LX2 Series:
Table of Contents

Advertisement

QUALIFIED
INSTALLER
Install Standoff s
The standoff s are supplied fl at. Bend them as shown
and fi x them to the top of the fi rebox.
Note: If installing with an all
steel framing, the top standoff s
are not necessary. Ensure that
the framing is self-supporting,
that is it NOT supported by the
engine.
Install 6-5/8" x 4" Vent Adapter (if
required)
This unit is supplied with a 5" x 8" vent outlet which
can be fi eld-converted to a 4" x 6-5/8" vent outlet by
installing the vent adapter supplied with the appliance.
42
INSTALLATION
Install HeatShift Take-off Collars
(required)
Install HeatShift take-off collars to appliance using
screws provided with appliance. See installation
Fold fl at
instructions packed with the HeatShift kits for details.
standoff s

Prepare Appliance for Wiring

Decorative Lighting and Remote Battery & Wall
Switch Kit (RBWSK)
The fi replace must be connected to the electrical
system of the home PRIOR to the fi nal position-
ing of the fi replace into the framing. The decorative
lighting above the fi rebed is operated by the fi replace's
remote control handset.
Wiring for the overhead lighting and RBWSK kit
is accessible from the rear panel of the appliance
and therefore it should be done BEFORE the
fi nal positioning of the fi replace in the framing.
Optional 2200ULK—Underbed Lighting Kit
Additionally, the 2200ULK—Underbed Lighting Kit
is off ered as an option (sold separately) to provide
decorative light under the fuel bed. This kit is optional
and if used, the wiring is also accessible from
the rear of the appliance and therefore, it must
be installed BEFORE the fi nal positioning of the
fi replace into the framing. It is operated by a dimmer
switch (not supplied) installed outside the fi replace.
Use the instructions provided with the kit for the
installation.
All electrical installations must be performed by
a qualifi ed electrician and must be electrically
wired and grounded in accordance with local codes,
or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 or the Canadian
Electrical Code, CSA C22.1.