Checking Pilot and Burner Flames

A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe. The main burner fl ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
Pilot Flame can be seen
towards the left side
Long Beach Driftwood Kit Correct Flame Picture
Pilot Flame can be seen
towards the left side
Murano Glass Fire Correct Flame Picture
Pilot Flame can be seen
towards the left side
Decorative Glass Set Correct Flame Picture
Pilot Flame can be seen
towards the left side
Splitwood Kit Correct Flame Picture
Pilot Flame can be seen
towards the left side
Rock & Shale Kit Correct Flame Picture
Pilot Flame
MAINTAINING YOUR FIREPLACE
Thermocouple Probe
must be in Flame
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make
sure that snow, trees, bushes, leaves, or other objects
do not obstruct it.
Examine the vent system and terminal regularly. We
recommend annually.