Summary of Contents for HEIDENHAIN QUADRA-CHEK 2000 Demo

  • Page 1 QUADRA-CHEK 2000 Demo User's Manual Evaluation Unit English (en) 06/2018...
  • Page 2 Contents Contents Fundamentals............................7 Software Installation........................11 Basic Operation..........................17 Software Configuration........................41 Quick Start............................47 Measurement Report Template....................69 ScreenshotClient..........................83 Index..............................89 List of Figures..........................91 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 3: Table Of Contents

    Symbols and fonts used for marking text..................10 Software Installation........................11 Overview............................... 12 Downloading the installation file.......................12 System requirements...........................12 Installing QUADRA-CHEK 2000 Demo under Microsoft Windows..........13 Uninstalling QUADRA-CHEK 2000 Demo..................15 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 4 Working in the workspace........................36 3.9.1 Operating elements in the workspace..................36 3.10 Using the Inspector..........................37 3.10.1 Operating elements of the Inspector..................37 3.11 Using measuring tools........................40 3.11.1 Measuring tools........................40 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 5 6.2.5 Defining data for a measurement report.................78 6.2.6 Saving a template........................81 6.2.7 Exiting or canceling the creation of a template...............81 Transferring a measurement report template to the unit..............81 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 6 7 .6.1 Configuring the storage location and file name for screenshots..........86 7 .6.2 Configuring the user interface language of screenshots............87 Creating screenshots........................... 88 Exiting ScreenshotClient........................88 Index..............................89 List of Figures..........................91 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 7: Fundamentals

    Fundamentals...
  • Page 8: Overview

    1.2.1 Demo software for demonstration of the device functions QUADRA-CHEK 2000 Demo is a software application you can install on a computer independently of the device. QUADRA-CHEK 2000 Demo helps you to become familiar with, try out or present the functions of the device.
  • Page 9: Intended Use

    Improper use QUADRA-CHEK 2000 Demo is not intended for any use other than the intended use. Any use for other purposes is prohibited, specifically: For productive purposes in production systems...
  • Page 10: Symbols And Fonts Used For Marking Text

    Identifies an item of a list Example: TTL interface EnDat interface Bold Identifies menus, displays and buttons Example: Tap Shut down The operating system shuts down Turn the power switch off HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 11: Software Installation

    Software Installation...
  • Page 12: Overview

    .exe File DemoBackup.mcc System requirements If you want to install QUADRA-CHEK 2000 Demo on a computer, the computer system must meet the following requirements: Microsoft Windows 7 or higher Screen resolution of at least 1280 × 800 recommended HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 13: Installing Quadra-Chek 2000 Demo Under Microsoft Windows

    Software Installation | Installing QUADRA-CHEK 2000 Demo under Microsoft Windows Installing QUADRA-CHEK 2000 Demo under Microsoft Windows Select the temporary storage folder into which you unpacked the downloaded file with the .zip extension Further information: "Downloading the installation file", Page 12 Run the installation file with the extension .exe...
  • Page 14 Software Installation | Installing QUADRA-CHEK 2000 Demo under Microsoft Windows Select the type of installation Activate or deactivate the option Screenshot Utility Figure 2: Installation wizard with activated demo software option and Screenshot Utility Next In the Select Start Menu Folder...
  • Page 15: Uninstalling Quadra-Chek 2000 Demo

    Unistallation starts, and the progress bar indicates the status of the unistallation process After uninstallation has been completed successfully, close the uninstallation wizard with OK The program has been successfully removed from your computer HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 17: Basic Operation

    Basic Operation...
  • Page 18: Overview

    3.2.1 Touchscreen and input devices The operating elements on the user interface from QUADRA-CHEK 2000 Demo are operated via a touchscreen or a connected mouse. To enter data, you can use the screen keyboard of the touchscreen or a connected keyboard keyboard.
  • Page 19: Gestures And Mouse Actions

    Gestures and mouse actions To activate, switch or move the operating elements of the user interface, you can use QUADRA-CHEK 2000 Demo's touchscreen or a mouse. Gestures are used to operate the touchscreen and the mouse. The gestures for operating the touchscreen may differ from the gestures for operating the mouse.
  • Page 20 Two-finger dragging initiates the following action In the Measure menu, moving the features view within the workspace HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 21: General Operating Elements And Functions

    The function is activated or deactivated Slider With the slider, you can continuously adjust values. Drag the slider to the desired position The selected value is displayed graphically or in percent HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 22 The new feature is added Close Tap Close to close a dialog Confirm Tap Confirm to conclude an activity Back Tap Back to return to the higher level in the menu structure HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 23: Quadra-Chek 2000 Demo - Startup And Shut-Down

    Basic Operation | QUADRA-CHEK 2000 Demo – startup and shut-down QUADRA-CHEK 2000 Demo – startup and shut-down 3.4.1 Starting QUADRA-CHEK 2000 Demo Before using QUADRA-CHEK 2000 Demo, you need to perform the steps for configuring the software. QUADRA-CHEK 2000 Demo...
  • Page 24: Shutting Down Quadra-Chek 2000 Demo

    Basic Operation | QUADRA-CHEK 2000 Demo – startup and shut-down 3.4.2 Shutting down QUADRA-CHEK 2000 Demo Tap Switch off in the main menu Tap Shut down QUADRA-CHEK 2000 Demo is shut down To shut down QUADRA-CHEK 2000 Demo in the Microsoft Windows window, also use the Switch-off menu.
  • Page 25: Setting The Language

    Operator type, the Measure menu with the workspace and the Inspector is displayed after the product has started up. If automatic user login is not active, the product opens the User login menu. Further information: "User login menu", Page 33 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 26: Main Menu Of The User Interface

    Management of the files that are available on the product Further information: "File management menu", Page 32 User login Login and logout of the user Further information: "User login menu", Page 33 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 27 Further information: "Settings menu ", Page 34 Switch-off Shutdown of the operating system or activation of energy- saving mode Further information: "Switch-off menu", Page 35 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 28: Measure Menu

    The selected geometry is displayed as an active feature. The geometries available on the geometry palette depend on the selected function. The tool palette provides the measuring tools required for conducting the selected measurement. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 29 The operating elements of the sensor palette are only available if software options are active. If one software option is active, the software option is displayed. If multiple software options are active, you can choose between the options. Optical edge detection (OED) HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 30 The operating elements of the tool palette are only available if a software option is active. They are only displayed in the manual measuring function if optical edge detection is activated. Crosshair Auto OED Crosshair Auto OED HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 31: Measurement Report Menu

    In the Measurement report menu, you can select report templates. A list of the templates is shown in the left-hand column. A preview of the selected template is displayed in the right-hand column. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 32: File Management Menu

    Figure 7: File management menu List of available storage locations List of folders in the selected storage location The File management menu shows an overview of the files stored in the unit’s memory. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 33: User Login Menu

    To log in another user, the logged-in user must first log out. Further information: "User login and logout", Page 24 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 34: Settings Menu

    The Settings menu shows all options for configuring the product. With the setting parameters, you can adapt the product to on-site requirements. The product provides various authorization levels that grant the user full or restricted access to management and operation functionality. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 35: Switch-Off Menu

    Tapping the axis key: Opens the input field for position value Holding down the axis key: sets the current position as zero point Reference mark search performed successfully Reference mark search not performed or no reference mark detected HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 36: Working In The Workspace

    Operating elements of the definition function Depending on the selected geometry, the input fields required for definition are displayed in the workspace. Figure 10: Operating elements of the Define function for the Circle geometry HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 37: Using The Inspector

    To display the features view in the workspace, tap Features preview The features view is displayed in the workspace The current content of the workspace switches to the Inspector HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 38 For each geometry time, it is possible to define which parameters are shown in the measurement result preview. The respec- tive geometry type determines which parameters are avail- able. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 39 If automatic measuring point acquisition is active, then a red dot will be shown in the operating element. The measuring points will be acquired after expiration of the set timeout HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 40: Using Measuring Tools

    Automatic acquisition of measuring points, e.g. on Auto OED circles and circular arcs Acquisition of light-to-dark transitions If the OED sensor traverses an edge, a measuring point is automatically acquired and added to the feature calculation. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 41: Software Configuration

    Software Configuration...
  • Page 42: Overview

    Further information: "Basic Operation", Page 17 Before you can use QUADRA-CHEK 2000 Demo correctly after successful installation, you need to configure QUADRA-CHEK 2000 Demo. This chapter describes how to perform the following settings:...
  • Page 43: Activating A License Key

    Software Configuration | Activating a license key Activating a license key With QUADRA-CHEK 2000 Demo, you can also simulate functions that are dependent on a software option. To do so, you must enable the software option with a license key. The required license key is stored in a license file in the folder structure of QUADRA-CHEK 2000 Demo.
  • Page 44: Copying The Configuration File

    Software Configuration | Copying the configuration file Copying the configuration file Before you can load the configuration data in QUADRA-CHEK 2000 Demo, you must first copy the downloaded configuration file DemoBackup.mcc to an area that can be accessed by QUADRA-CHEK 2000 Demo.
  • Page 45: Uploading The Configuration File

    Further information: "Activating a license key", Page 43 In order to configure QUADRA-CHEK 2000 Demo for the application on the computer, you must upload the configuration file DemoBackup.mcc. Tap Settings in the main menu The product settings are displayed...
  • Page 46: Setting The Language

    Tap Settings in the main menu Tap Service Tap Product designation Select the desired version You are now prompted to perform a restart QUADRA-CHEK 2000 Demo is ready for use in the desired version HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 47: Quick Start

    Quick Start...
  • Page 48: Overview

    QUADRA-CHEK 2000 operating instructions. Make sure that you have read and understood the "Basic Operation" chapter before carrying out the actions described below. Further information: "Basic Operation", Page 17 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 49: Conducting A Measurement

    Figure 13: Example of aligning a 2-D demo part Measured objects are usually aligned in the following steps: 1 Measuring the alignment 2 Measuring a straight line 3 Constructing the zero point HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 50 The alignment is displayed in the feature list of the Inspector The measurement result preview is now displayed Figure 14: Alignment feature in the feature list with Measurement result preview HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 51 The line is displayed in the feature list of the Inspector The measurement result preview is now displayed Figure 15: Line feature in the feature list with Measurement result preview HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 52 The workpiece coordinate system for the measured object has been determined Tap Features preview The coordinate system is shown in the workspace Figure 16: Workspace with zero point displayed in the coordinate system HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 53 To measure features, you can use the geometries of the geometry palette. Figure 17: Examples of measuring a 2-D demo part The section below describes measuring the following features: 1 Circle 2 Slot 3 Blob HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 54 A new feature is calculated from the captured measuring points and the selected geometry The measured circle is displayed in the features preview The measurement result preview is now displayed HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 55 Quick Start | Conducting a measurement Figure 18: Circle feature in the feature list with Measurement result preview HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 56 The measured slot is displayed in the features preview The measurement result preview is now displayed Figure 19: Slot feature in the feature list with Measurement result preview HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 57: Displaying And Editing The Measurement Results

    Displaying and editing the measurement results You can edit the measured features immediately after capturing the measuring points. Drag individual features into the workspace and edit them in the Details dialog. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 58 Tap the input field containing the current name Enter a new name for the feature Confirm entry with RET The new name is displayed in the feature list Tap Close to close the dialog HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 59 In the Fitting algorithm drop-down list, select the desired fitting algorithm (e.g., Min. circumscribed) The feature is displayed according to the selected fitting algorithm Figure 22: Circle feature with new fitting algorithm Tap Close to close the dialog HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 60 The 2-D profile geometry type is currently not yet supported. The feature is displayed in the new form Figure 23: Type of geometry changed from Slot to Point Tap Close to close the dialog HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 61 The tab for tolerancing the selected feature is displayed Tap the size tolerance X An overview of the selected size tolerance appears Figure 25: Overview of Size tolerance with activated size tolerance X HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 62 Symbols are used to display the result of the tolerance check on the Tolerances tab and, after closing the dialog, in the feature list Activated tolerances are maintained One or more activated tolerances are exceed- HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 63 You can add an annotation to every feature in the features view (e.g., measurement information or informational texts). Figure 26: Operating elements for annotations and feature with annotations 1 Edit annotations operating element Operating elements for adding annotations Measurement information Explanatory text HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 64: Creating A Measurement Report

    Select drop-down list All features in the list and in the features preview are activated and displayed in green Figure 27: Measurement report menu with feature list and features view HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 65 Only the non-selected features are shown. Creation type Only features that fulfill the selected character- istic are shown. Is not Only features that do not fulfill the selected characteristic are shown. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 66 Enter the name Demo1 for the measurement report Confirm entry with RET Tap Save as The measurement report is exported in the selected format and stored in the storage location HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 67 A preview image as well as information about the file are displayed Figure 29: Preview of the measurement report and file information To display the measurement report, tap View The file contents are displayed Tap Close to close the view HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 69: Measurement Report Template

    Measurement Report Template...
  • Page 70: Overview

    Overview This chapter describes how you can create your own measurement report templates with QUADRA-CHEK 2000 Demo and transfer them to your unit so that you can use the templates for creating measurement reports on your unit. Make sure that you have read and understood the "Basic Operation"...
  • Page 71: Creating And Editing A Template

    Opening a new template with the editor Editing the default settings for the measurement report Configuring the page header Configuring the report header Defining the data for the measurement report Saving the template HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 72: Opening A New Template With The Editor

    Figure 31: Measurement report menu with the list of templates and the Add button Tap Add to create a new template The Default settings for the template are displayed Figure 32: Editor for measurement report templates HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 73: Editing The Default Settings For The Measurement Report

    To show the page header in the template, activate Display page header with the ON/OFF sliding switch To show the report header in the template, activate Display report header with the ON/OFF sliding switch HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 74: Configuring The Page Header

    "Grid" operating element for displaying and hiding the auxiliary lines in the editor. Tap Grid to display or hide the grid of auxiliary lines The grid of auxiliary lines is always active. All fields of the form are automatically aligned with HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 75 Drag the form field to the desired position in the template If form fields overlap, the affected area is highlighted in red The change to the form field is applied HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 76: Configuring The Report Header

    The list shows the form fields that can be inserted into the selected section of the template. "Grid" operating element for displaying and hiding the auxiliary lines in the editor. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 77 Drag the square handle of the corresponding form field to the desired size If form fields overlap, the affected area is highlighted in red The change to the form field is applied HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 78: Defining Data For A Measurement Report

    "Grid" operating element for displaying and hiding the auxiliary lines in the editor. Tap Grid to display or hide the grid of auxiliary lines The grid of auxiliary lines is always active. All fields of the form are automatically aligned with HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 79 Creation type The symbol for the process with which the feature has been generated is inserted (measuring, constructing, or defining). HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 80 Segment +3: +++ Reference, bonus The reference feature of a tolerance applied to the feature is inserted. If a material requirement is being used, the exist- ing tolerance bonus is inserted. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 81: Saving A Template

    Transferring a measurement report template to the unit You can transfer a measurement report template from a computer to the unit over a network or via a USB mass storage device. HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 82   Internal Reports custom_templates Tap Select The file is stored on the product The template appears in the Measurement report menu and can be used for creating measurement reports HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 83: Screenshotclient

    ScreenshotClient...
  • Page 84: Overview

    ScreenshotClient | Overview Overview The standard installation of QUADRA-CHEK 2000 Demo also contains the ScreenshotClient program. With ScreenshotClient, you can take screenshots of the demo software or the unit. This chapter describes how ScreenshotClient is configured and used. Informationen about ScreenshotClient With ScreenshotClient, you can take screenshots of the active screen of the demo software or the unit from a computer.
  • Page 85: Starting Screenshotclient

    Further information: "Starting QUADRA-CHEK 2000 Demo", Page 23 Tap Connect A connection with the demo software is established The status message is updated The Identifier and Language input fields become active HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 86: Connecting Screenshotclient With The Unit

    Enter the path to the storage location and the name for the screenshots into the Identifier input field Use the following syntax to enter the path and file name for screenshots: [drive]:\[folder]\[file name] ScreenshotClient will save all screenshots to the storage location entered HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 87: Configuring The User Interface Language Of Screenshots

    Use the arrow keys to select all in the Language input field The all language code is shown in red ScreenshotClient creates the screenshots in all available user interface languages HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 88: Creating Screenshots

    The status message is updated: Figure 38: ScreenshotClient after screenshot has been created successfully Exiting ScreenshotClient Disconnect The connection to the demo software or the unit is terminated Tap Close ScreenshotClient is exited HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 89: Index

    Operation....... 19 Language Configuration data.... 44, 45 Tapping........19 setting......25, 46 Downloading the installation Two-finger drag...... 20 License key file.......... 12 Activating....... 43 installation......13 Shut-down......24 OED sensor HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 90 Measurement report menu..31 measure menu...... 28 Settings menu....... 34 Switch-off menu..... 35 User login menu....33 User login........24 Menu........33 Using Measuring tools..... 40 Workspace......... 36 operating elements....36 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 91: List Of Figures

    The data table of a measurement report template..............78 Image 36: ScreenshotClient user interface....................84 Image 37: ScreenshotClient has been started (not connected yet)............85 Image 38: ScreenshotClient after screenshot has been created successfully......... 88 HEIDENHAIN | QUADRA-CHEK 2000 Demo | User's Manual | 06/2018...
  • Page 92 DR. JOHANNES HEIDENHAIN GmbH Dr.-Johannes-Heidenhain-Straße 5 83301 Traunreut, Germany  +49 8669 31-0  +49 8669 32-5061 E-mail: info@heidenhain.de Technical support  +49 8669 32-1000 Measuring systems  +49 8669 31-3104 E-mail: service.ms-support@heidenhain.de NC support  +49 8669 31-3101 E-mail: service.nc-support@heidenhain.de NC programming ...

Table of Contents