JAI GO-5101M-PMCL User Manual page 51

5.1m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

Item
User Set Load
User Set Save
k) JAI Custom Control ALC
ALC Reference
ALC Area Selector
ALC Area Enable
ALC Area Enable All
ASC Min.
ASC Max.
AGC Min.
AGC Max.
AGC/ASC Control Speed
ALC Status
l) JAI Custom Control AWB
AWB Area Selector
AWB Area Enable
AWB Area Enable All
AWB Control Speed
AWB Status
m) JAI Custom Control Blemish
Blemish Enable
Blemish Detect
Blemish Detect Threshold
Blemish Detect Position Index
Setting range
10 to 95
Low Right,
Low Mid-Right,
Low Mid-Left,
Low Left,
Mid-Low Right,
Mid-Low Mid-Right,
Mid-Low Mid-Left,
Mid-Low Left,
Mid-High Right,
Mid-High Mid-Right,
Mid-High Mid-Left,
Mid-High Left,
High Right,
High Mid-Right,
High Mid-Left,
High Left
True, False
Off, On
100 to 7999999
101 to 8000000
100 to 1599
101 to 1600
1 (slow) to 8 (fast)
Low Right to High Left
True, False
True, False
1 to 8
True, False
0 to 100
0 to 511
— 51 —
GO-5101M-PMCL / GO-5101C-PMCL
Default value
Load user settings.
Save the current setting values as user
settings.
Configure JAI ALC settings. These
settings are also used for AGC (auto gain
control).
50
Set the target level for ALC. (unit: %)
Low Right
Select the area for which to configure
[ALC Area Enable].
False
Enable/disable the photometry area
selected in [ALC Area Selector].
Off
On: Operate ALC with all areas
designated as photometry areas,
regardless of the individual enabled/
disabled photometry area states
configured in [ALC Area Selector].
Off: Operate ALC according to the
individual enabled/disabled
photometry area states configured in
[ALC Area Selector].
100
Set the minimum value for the Exposure
Auto (ASC) control range.
8216
Set the maximum value for the Exposure
Auto (ASC) control range.
100
Set the minimum value for the Gain Auto
(ASC) control range.
1600
Set the maximum value for the Gain Auto
(ASC) control range.
4
Set the reaction speed for AGC/ASC.
(8 is the fastest.)
Display the counter ALC.
Configure settings for JAI AWB.
Low Right
Select from the 16 metering areas for
AWB individually.
False
Enable / disable the selected AWB
metering area.
True
Enable / disable all AWB metering area.
4
Select the AWB reaction speed. (for
continuous)
Idle
Display the counter AWB.
Configure settings for JAI white blemish
correction.
True
Enable/disable blemish correction.
Execute blemish detection
10
Set the blemish detection threshold.
0
Select the index for the target blemish
coordinates (Blemish Data Position X/Y).
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-5101c-pmcl