Item
Sequencer Reset
g) Digital IO Control
Line Selector
Line Mode
Line Inverter
Line Status
LineSource
Line Format
User Output Selector
User Output Value
h) Pulse Generators
Clock Pre-scaler
Pulse Generator Clock (MHz)
Pulse Generator Selector
Setting range
—
Line1 - TTL Out,
Line4 - TTL In,
Line7 - CC1,
NAND Gate 0 In 1,
NAND Gate 0 In 2,
NAND Gate 1 In 1,
NAND Gate 1 In 2
Input,
Output
True, False
True, False
Low, High,
Frame Trigger Wait,
Frame Active,
Exposure Active,
FVAL,
Pulse Generator 0,
User Output 0,
User Output 1,
Line4 - TTL In,
Line7 - CC1,
Nand 0 Out,
Nand 1 Out
—
User Output 0,
User Output 1
True, False
1 to 4096
0.018127 to 74.25
Pulse Generator 0
— 49 —
GO-5101M-PMCL / GO-5101C-PMCL
Default value
—
Reset the current index number to the
number configured in [Sequencer Set
Start].
Configure settings for digital input/output.
Line1 - TTL Out
Select the input/output to configure.
Output
Display the input/output status (whether it
is input or output).
False
Enable/disable polarity inversion for the
selected input signal or output signal.
False
Display the status of the input signal or
output signal (True: High, False: Low).
Low
Select the line source signal for the item
selected in [Line Selector].
TTL
Display the current I/F type.
0: User Output 0
Set the user output signal.
False
Set the value for the User Output selected
in [User Output Selector].
Configure pulse generator settings.
165
Set the division value for the prescaler
(128-bit length) using the pixel clock as
the base clock.
0.45
Set the clock used for the pulse
generator.
This value is calculated using the [Clock
Pre-scaler] value as a base.
Pulse Generator 0
Select the pulse generator.
Description