■ When [Exposure Mode] is [Trigger Width]

Example: When [Trigger Source] is set to [Line 7 - CC1]
• Trigger overlap: Off
Trigger
Sensor
Exposure
EEN
FVAL
Tap
Geometry
1X2-1Y
1X2-1Y
1X2-1Y
1X3-1Y
1X3-1Y
1X4-1Y
1X4-1Y
• Trigger overlap: Readout
Trigger
Sensor
Exposure
EEN
FVAL
A
Period from
CL Pixel
Trigger start
Clock
edge to
(MHz)
Exposure
start[B](usec)
start[A](usec)
37.125
101
74.25
51
84.85
45
37.125
68
74.25
42
37.125
51
74.25
42
A
— 32 —
Next trigger disabled
D
Readout duration
B
(= Height x Line Period)
Period from
Period FVAL
Exposure
end to next
end to FVAL
trigger start[C]
(usec)
851
851 − Expo
(Current) +
Expo (Next)
435
934 − Expo
(Current) +
Expo (Next)
384
939 − Expo
(Current) +
Expo (Next)
573
906 − Expo
(Current) +
Expo (Next)
354
942 − Expo
(Current) +
Expo (Next)
436
937 − Expo
(Current) +
Expo (Next)
314
952 − Expo
(Current) +
Expo (Next)
Next trigger
disabled
C
Next trigger input enabled
D
Readout duration
B
(= Height x Line Period)
GO-5101M-PMCL / GO-5101C-PMCL
Next trigger
input enabled
t5
Max
Min
Exposure
Exposure
[msec]
[usec]
69.116
34
34.558
17
30.336
15
46.189
23
27.847
14
34.669
17
27.847
14