Maximum Frame Rate Period Formula - JAI GO-5101M-PMCL User Manual

5.1m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

■ Maximum frame rate period formula

During continuous operation ([Frame Start] trigger is [Off] or [Exposure Mode] is [Off])
• Maximum frame rate of sensor
FR_Cont = 1 / {H Period × (Height + 34)}
When the exposure time is longer than the frame interval
• Maximum exposure time at maximum frame rate
MaxExposureTime_TrOlrd = (1 / FR_Cont) - (14 × H Period)
• Exposure time outside of frame interval
NonOverlapExposureTime = ExposureTime - MaxExposureTime_TrOlrd
However, NonOverlapExposureTime calculation results that are 0 or below will be considered as 0.
• Maximum frame rate
FR_ContLongExposure = 1/{(1/FR_Cont) + NonOverlapExposureTime}
When [Frame Start] trigger is [On] and [Trigger OverLap] is [Off]
• Maximum frame rate of sensor
FR_Cont = 1 / {H Period × (Height + 34)}
• Maximum frame rate
FR_TrOloff = 1/{1/FR_Cont) + ExposureTime}
When [Frame Start] trigger is [On] and [Trigger OverLap] is [Readout]
• Maximum frame rate of sensor
FR_Cont = 1 / {H Period × (Height + 34)}
• Exposure time possible within frames
MaxOverlapTime_TrOlrd = (1 / FR_Cont) - (14 × H Period)
• Exposure time outside of frame interval
NonOverlapExposureTime_TrOlrd = ExposureTime - MaxOverlapTime_TrOlrd
However, NonOverlapExposureTime_TrOlrd calculation results that are 0 or below will be considered
as 0.
For TriggerWidth, the trigger pulse is equivalent to ExposureTime.
• Maximum frame rate
FR_TrOlrd = 1 / {(1 / FR_Cont) + NonOverlapExposureTime_TrOlrd}
Full size - Vertical Binning =1(OFF)
Tap Geometry
1X2-1Y
1X2-1Y
1X2-1Y
1X3-1Y
1X3-1Y
1X4-1Y
1X4-1Y
CL Pixel Clock (MHz)
37.125
74.25
84.85
37.125
74.25
37.125
74.25
— 28 —
GO-5101M-PMCL / GO-5101C-PMCL
H Period [usec]
Frame Rate (fps)
33.293
16.646
14.613
22.249
13.414
16.700
13.414
14.3
28.7
32.7
21.5
35.6
28.6
35.6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-5101c-pmcl

Table of Contents