Control Without External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Trigger Selector (trigger operation)
Trigger Mode
Exposure Mode
Exposure Time
Exposure Auto
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Specify the exposure time in [Exposure Time].
The setting value for the exposure time can only be changed when [Exposure Auto] is set to [Off].
If [Exposure Auto] is set to [Continuous], temporarily set it to [Off] before changing the exposure
time.
3
Set [Trigger Mode] to [On].
4
If necessary, change the [Exposure Auto] setting.
When not Controlling the Exposure Time
Configure the settings as follows.
Exposure Mode
The exposure will be performed with an exposure time equal to 1 / frame rate.
Step 5: Adjusting the Image Quality
Adjust the image quality using the gain and white balance (GO-5101C-PMCL only) functions.
To adjust the image quality
The display level must be changed from [Beginner] to [Guru].
Item
Item
— 19 —
Setting value / selectable range
Frame Start
Off
Timed (control via exposure time)
Varies depending on the Tap Geometry and CL Pixel Clock
settings.
Off, Continuous
Setting value / selectable range
Off
GO-5101M-PMCL / GO-5101C-PMCL