Tap
Geometry
1X2-1Y
1X2-1Y
1X2-1Y
1X3-1Y
1X3-1Y
1X4-1Y
1X4-1Y

Gain Control

[Analog All] can be used for gain control for both the monochrome and color camera. [Analog All]
(master gain) uses the sensor's internal gain function and consists of analog gain + digital gain.
Analog gain is used for lower gain, and analog gain + digital gain is used when the gain becomes
high. R and B can be configured individually as digital gain on the GO-5101C-PMCL.
 For details on how to configure the settings, see "Adjusting the Gain" (page 20).
The relationship between the gain setting value, gain amplification, and dB value is as follows. For
example, a gain amplification of x5.62 will be 15 dB.
Monochrome
Gain
Gain
setting
Gain adjustment range (monochrome)
amplification
value
1600
x16
100
x1
Bayer color
Gain
Gain
setting
Gain adjustment range (Bayer color)
amplification
value
Master
39dB
X89.12
X16
1600
X7.15
15dB
X5.62
0
X1
X0.45
-7dB
Period from
CL Pixel
Trigger start
Clock
edge to
(MHz)
Exposure
start[B](usec)
start[A](usec)
37.125
101
74.25
51
84.85
45
37.125
68
74.25
42
37.125
51
74.25
42
24dB
0dB
Red
Master
Blue
24dB
0dB
Period from
Next trigger
Exposure
start prohibited
end to FVAL
period[C](usec)
851
466
435
233
384
205
573
311
354
188
436
234
314
188
Gain setting
value (scaling)
R&B
37876 (X5.62)
15dB
0dB
0 (X1)
–7dB
–4533 (X0.45)
37876 (X5.62)
15dB
0dB
0 (X1)
–7dB
–4533 (X0.45)
— 33 —
GO-5101M-PMCL / GO-5101C-PMCL
Period from
Trigger end
Min
edge to
Exposure
Exposure
[usec]
end[D](usec)
128
34
61
17
53
15
83
23
48
14
61
17
48
14