VERSION 12/2018
3
IDENTIFICATION
3.1
EXPLOSION PROTECTION IDENTIFICATION
As defined in the Directive 2014/34/EU (ATEX), the device is suitable for use in potentially
explosive areas.
Device type:
Manufacturer:
II 2G X
CE
Ex
II
2
G
X
3.2
IDENTIFICATION "X"
The maximum surface temperature corresponds to the permissible product temperature.
This and the permissible ambient temperature can be found in Chapter 5.4.2.
Safe Handling of WAGNER Spray Devices
Mechanical sparks can form if the device comes into contact with metal.
In an explosive atmosphere:
knocking or pushing metal against metal is to be avoided;
do not drop the device.
Ignition temperature of the coating product
Ensure that the ignition temperature of the coating product is above the maximum
surface temperature.
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges.
Flames or sparks can form during discharge.
Remove deposits from the surfaces to maintain conductivity.
ORDER NUMBER DOC 350941
GA 250AL / GA 400AL Airless automatic gun
Wagner International AG
CH-9450 Altstätten, Switzerland
European Communities
Symbol for explosion protection
Device class II
Category 2 (zone 1)
Ex-atmosphere gas
Special notice
GA 250AL_GA 400AL
10