To the installer

It´s now time for the installation of the boiler. Try to follow the examples we are describing for a safe
installation. After the installation, be careful to educate the end user of the boiler how the system is used
and maintained, this is to avoid unnecessary stops an problems.
Location
The boiler shall be placed on a firm foundation, try also to place the boiler as horizontally as possible,
this to avoid airpockets in the boiler. Keep in mind the laws and regulations regarding distances to com-
bustible materials.

The boiler room

The boiler room shall be constructed according to current laws and regulation, if uncertain regarding this,
contact concerned authority. You need good ventilation in the boiler room to get the best performance of
the Woody Lambda.
The accumulator
It´s important that the accumulators are well isolated, this is to get as small heatlosses as possible. To get
a good comfort regarding the number of times you have to be in boiler room, you need at least 1500l of
accumulation volume.
The chimney
The chimney should have a diameter of at least 150mm,if you have a chimney with less diameter, Effecta
should be consulted before installation. The draft in the chimney should at low temperature be approx
15 pa. It´s important that the chimney is tested and approved by concerned authority before a new boiler
is installed. If the draft is to hefty a draft stabilator might be needed. If you have a tall chimney and a flue
gas temperature below 170degrees there is a risk of condensation, which in the long run can be harmful
to the chimney. Adequate temperature 1 metre from the vent of the chimney is 70-80degrees.
If the chimney is tall and wide it may result in to much draft which can lead to too much gasification and
too much fire in the grate. This can be prevented by installing a draft stabiliser.