Cleaning system boiler

Function and service
Cut the power to the boiler before servicing. The solenoid is mounted on the boiler to keep
the convective part clean. It is controlled from the menu "Cleaning" on the control panel. It
can be set to work/not work in different times during the day.
The solenoid
The solenoid is mounted on the right side of the soot
hatch on the top of the boiler. The solenoid flips the
turbulators up and down to keep the tubes clean.
Lifting shaft
The shaft is pulled up by the magnet making the
turbulators also being pulled up.
The turbulators
The turbulators in the tube helps reducing the flue
gas temperature and also cleaning the tubes when
pulled up and down.
Suspension
On every suspension there are two turbulators
that is removed when cleaning the tubes with
a brush.
Flipper
Flips when the solenoid activates.