Connect The Nitrogen Supply; Flammable/Pyrophoric Materials - Edwards iH80 Instruction Manual

Ih series. dry pumping system
Table of Contents

Advertisement

3.6

Connect the nitrogen supply

Ensure that your nitrogen supply conforms to the requirements given in the Technical Data Section. If it doesn't,
the flow sensors may not operate correctly, the gas pipelines may become blocked or the iH system may be
damaged.
Refer to
Figure
3, item 8.
For optimum nitrogen, ensure that your nitrogen supply complies with
3.6.1

Flammable/pyrophoric materials

You must obey the instructions and take note of any precautions given below to ensure that
pumped gases do not enter their flammable ranges.
When flammable or pyrophoric materials are present within the equipment you must:
Not allow air to enter the equipment
Ensure that the system is leak tight
Ensure that pumped gases do not enter their flammable range. This can be achieved by diluting flammable
gases/vapours or oxidisers in the pump by supplying sufficient inert gas purge, for example dilution with
nitrogen to below one quarter LEL (lower explosive limit) or, if that is not practical, to below 60% LOC
(limiting oxidant concentration).
For further information please refer to Semiconductor Pumping Application Guide (Publication no. P411-00-
090) or contact Edwards: refer to the address page at the rear of this manual for details of your nearest
Edwards company.
© Edwards Limited 2008. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
CAUTION
Table
WARNING
A590-00-880 Issue D
2.
Page 17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ih600Ih1800Ih1000Ih1800nrvIh1800htxIh1800nrv htx ... Show all

Table of Contents