Connect The Cooling-Water Hoses; Accessories - Edwards iH80 Instruction Manual

Ih series. dry pumping system
Table of Contents

Advertisement

A590-00-880 Issue D
3.11

Connect the cooling-water hoses

Do not leave the cooling-water supply turned on until after you complete the electrical installation
of the pump. If you do, condensation may form inside the enclosure and there may be a risk of
electric shock.
Notes:
1. For optimum water-cooling, ensure that your cooling-water supply complies with the data given in
Table 1
and that they are connected in parallel. Refer to
recommend that quick connectors be used to reduce the risk of water spillage during connection/
disconnection.
2. For minimum water consumption, regulate the cooling-water flow to the iH system.
Connect the cooling-water supply as follows:
1. Use 3/8 inch BSP male pipe fittings (which you must supply) to fit the female quick-release connector to the
cooling-water supply hose and to fit the male quick-release connector to the cooling-water return hose.
2. Remove the dust-caps from the cooling-water inlet and outlet.
3. Connect your water return hose to the cooling-water outlet
hose to the cooling-water inlet
4. Turn on the cooling-water supply.
5. Inspect the water hoses, pipelines and connections and check that there are no leaks.
Turn off the water supply while you complete the remainder of the installation procedures.
3.12

Accessories

Refer to the individual accessories manuals for installation, information, refer to
The disconnect box when fitted, is used to energize and isolate the power supply to the system. It also allows the
isolation of the electrical supply during an emergency, and for maintenance and trouble shooting the system, thereby
satisfying SEMI S2 requirements. The photohelic switch/gauge when fitted, allows monitoring for loss of extraction
from the enclosure, thereby satisfying SEMI S2 requirements.Refer to the individual accessories manuals for
information about installation.
Page 24
WARNING
(Figure
3, item 3).
Edwards and the Edwards logo are trademarks of Edwards Limited.
Figure
3, items 3 and 6. Edwards would
(Figure
3, item 6) and connect your water supply
Section
© Edwards Limited 2008. All rights reserved.
7.3.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ih600Ih1800Ih1000Ih1800nrvIh1800htxIh1800nrv htx ... Show all