General Data - Edwards iH80 Instruction Manual

Ih series. dry pumping system
Table of Contents

Advertisement

A590-00-880 Issue D
2.5

General data

Item
Description
Electrical
Supply voltage 3-phase
Recommended fuse / isolator
rating
Voltage tolerance range
208 V and 415 V, 50 Hz only
Installation category
Harmonic voltage distortion factor
Fuse types and ratings
Water cooling system
Maximum supply pressure
Minimum supply pressure
Minimum flow rate required
Supply temperature range
Typical pressure differential across
supply and return
Water type
Maximum particle size
Acidity
Hardness
Resistivity
Solids (turbidity)
Materials in contact with cooling
water
Connections
Water cooling inlet
Water cooling outlet
Nitrogen inlet
Materials in contact
Pump, shaft and rotors
with process gas
Seals
Gas System
Operating conditions
Intended use
Ambient temperature range:
Relative humidity
Maximum operating altitude
Pollution degree
*
With cooling water supply temperature of 20°C and flow rate of 3 l min
Page 12
Table 6 - Technical data
F8
F9
F10
*
Operating
Storage
Edwards and the Edwards logo are trademarks of Edwards Limited.
Rating
200-208/380 - 415 V, 50 Hz a.c.
200-208/230/460 V, 60 Hz a.c.
Full load current rating, refer to
Table 3
Class CC fuse rated to 600V.
+/- 10%
+6% /-10%
II (IEC 664)
5%
T1.6 A, 250 V
T3.15 A, 250 V
T5.0 A, 250 V
100
36
Refer to
Table 1
10-30
15
Treated or non-corrosive industrial
0.03
6.5 to 8.0
<100
>1
<100
Stainless steel, Nitrile, PTFE, copper,
brass and fluoroelastomer
3/8 inch BSP male quick connector
3/8 inch BSP female quick connector
1/4 inch tube fitting
Cast Iron, Steel, SG iron
PTFE and fluoroelastomer
Stainless steel, Aluminium, brass and
fluoroelastomer
Indoor
5 to 40
-45 to 55
10 to 90
2000
2 (IEC 61010)
-1
.
© Edwards Limited 2008. All rights reserved.
Units
V
V
psig
psig
°C
psig
2
mm
pH
ppm
k cm
ppm
°C
°C
%RH
m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ih600Ih1800Ih1000Ih1800nrvIh1800htxIh1800nrv htx ... Show all

Table of Contents