Table 33: Screen 529 Auto Zero Feature; Figure 70: Auto Zero Screen - Ohmart Vega W-4510 Technical Reference Hardware Manual

Weigh scale with gen 2000 electronics model / with frequency output
Table of Contents

Advertisement

Appendix II: Auto zero feature
Item#
Parameter Name
2700
AZ ENABLE
2701
AZ STATUS
2702
AZ CYCLES
2703
AZC 1 VECTOR
2704
AZC 2 VECTOR
2705
AZC 3 VECTOR
2706
AZ PAUSE TIME
2707
AZ TIMER
2708
AZ STATE
2709
AZ SAMPLING
2710
AZ CUTOFF ENABLE
2711
AZ CUT OFF
VECTOR
Item 2701 displays whether the auto zero is enabled or not
Item 2706 is the wait state to see that all process is cleared (entered in ¼ seconds)
The auto zero feature starts a zero and if it finishes one it will start a new one.
Item 2702 displays how many times it has gone through the auto zero cycle this session. If it
gets through at lease one auto zero then it will save the average of all cycles completed.
Note: The list of auto zeros are not in chronological order. Look for the oldest entry. Only the
last 20 zeros are saved.
140
529
APP CODE ACCESS
ADR
2700
_
CURRENT VAL
NEW VAL
0
_

Figure 70: Auto zero screen

Table 33: Screen 529 Auto Zero feature

Parameter description
0=AZ Disabled, 1=AZ Enabled
0=AZ not currently running. 1=AZ sample interval active
If AZ is active, how many AZs done so far
Address of blending line belt LDC (0=running, 1=not running)
Address of dry bin belt LDC (0=running, 1=not running)
Address of undefined LDC (not used)
Amount of time (in quarter seconds) to wait after dry bin LDC trips before
starting AZ counter used to determine when the pause time has elapsed
Time has elapsed
Used internally to synchronize AZ function
1=wait over, 2=still waiting
0=Disable, 1=Enable
2709 for AZ-time out
W-4510 Weigh Scale Technical Reference Manual

Advertisement

Table of Contents
loading

Table of Contents