Table 32: Screen 528 Linearizer Block; Figure 69: Linearizer Curve Screen - Ohmart Vega W-4510 Technical Reference Hardware Manual

Weigh scale with gen 2000 electronics model / with frequency output
Table of Contents

Advertisement

Screen 528 Linearizer Block
The base address for screen 528 LINEAR CURVES is 529, item 512.
The n on the top line is a number from 0 to 9. This number is the current linearizer curve that
you are accessing. The value of n can be incremented by pressing the HELP key.
Item#
Parameter Name
0
CURVE
1
2
...
40
HIGH END POINT
OF CURVE
41
CURVE STATUS
42
LOW PRODUCT
VALUE
43
HIGH PRODUCT
VALUE
44
SPARE
45
SPARE
46
SPARE
47
SPARE
48
SPARE
49
SPARE
W-4510 Weigh Scale Technical Reference Manual
528 LINEAR CURVES
ITEM
000
NEXT=000
CURRENT VAL
NEW VAL
00000
00000

Figure 69: Linearizer curve screen

Table 32: Screen 528 Linearizer block

Parameter description
Start of 40-slope linearizer curve. Uses 41 locations. Curve in normalized units,
usually 0 to 10,000. (i.e., 0–100%)
The percent of process span that corresponds to 2.5% of the count range
The percent of process span that corresponds to 5.0% of the count range
0=no curve data entered, 1=40 point curve entered- 41 locations
Value of low end of curve in product units. These are Ohmart product units for
calibration
Value of high end of curve in product units for calibration purposes
Appendix I: Parameter blocks