9.1 Main technical parameters
Parameter
Voltage
Phase
Frequency
Max.Current
Power Factor
Max.output power
Voltage range
Voltage resolution
Voltage accuracy
Temp. coefficient
Max Current(rms)
Max Current(peak)
Total Harmonic Distortion(T.H.D)
Crest Factor
Line Regulation
Load Regulation
Response Time
Output phase
Max.output power
Chapter9 Technical Specifications
This chapter will introduce the main technical parameters of IT7600, such as
rated voltage/current/power and so on. Besides, this part will introduce the
working environment and storage temperature.
*1
1-150Vac
2-300Vac
1-150Vac
2-300Vac
*3
Copyright ©ITECH Electronic
IT7622
AC Input
220Vac±10%or 110Vac±10%
single phase
47-63Hz
20A/40A
0.7(typical)
AC Output
750VA
2V-300V,1V-150V/2V-300V Auto
10mV
±0.2%+(0.2%+0.2%×Kfreq)×FS
±(0.04% per degree from 25℃)
0-6Arms
0-3Arms
0-18Apeak
0-9Apeak
≤0.5% at 10-500Hz (Resistive Load)
≤2% at 501-5000Hz (Resistive Load)
≤0.1%FS(Resistive Load)
≤0.5%FS(Resistive Load)
≤100us(typical)
single phase
DC Output
375W
Co., Ltd.
www.tehencom.com
Technical Specifications
*2
3
V1.3
75
Need help?
Do you have a question about the IT7622 and is the answer not in the manual?
Questions and answers