Page 3
Warranty ITECH warrants that the product will be free from defects in material and workmanship under normal use for a period of one ( 1) year from the date of delivery ( except those described in the Limitation of Warranty below).
Page 4
Failure to comply with these precautions or specific warnings elsewhere in this manual will constitute a default under safety standards of design, manufacture and intended use of the instrument. ITECH assumes no liability for the customer’s failure to comply with these precautions.
Page 11
1.1 Brief Introduction ITECH IT7900P series represents a new generation of programmable, full power source and sink 4-Quadrant grid simulators and also can perform as a 4- Quadrant power amplifier, providing the flexibility to test widest range of grid-tied devices, including PCS, energy storage systems, micro grids, BOBC (V2X) and power-related hardware in the loop emulation (PHiL).
Page 13
The IT7900P series supports the following optional accessories (sold separately), the details are as below: The interface expansion slot provided on the rear panel of the IT7900P series instrument allows users to flexibly expand according to their needs. Different interface cards can be selected to achieve different functions.
Page 20
⚫ ITECH 27U and 37U cabinets are equipped with hoisting rings as standard on the top. It is recommended to use a crane equipped with a four-leg hoisting belt structure for horizontal hoisting and moving, and ensure that the four hoisting belts are the same length to avoid cabinet skew during movement.
Page 21
5 Number key 6 Up, down, left and right key and enter key 7 Rotary knob 8 Vent hole 2.4 Keyboard The keyboard introduction of IT7900P series Power Supply is shown as follows. Keys Description Print Used for saving screen images...
Page 23
[Shift]+ [7] (Help) Obtain the help information. 2.5 Push-on Knob The IT7900P series Power Supply provides a knob on the front panel as shown in the next figure. The functions of the posh-on knob is described as follows. ⚫...
Page 24
Instrument Introduction 2.6 Rear Panel The rear panel of the IT7900P series 3U model is shown below. Name Description ground terminal Ground screw for making chassis ground connections. Output AC or DC output terminals and chassis ground terminals(M6) terminals, used to connect DUT.
Page 25
Port spacing is 10.16mm, screw M4 hole size. The rear panel of IT7900P series 15U and above series cabinets are the same. Take IT7945P-350-270 as an example, the rear panel is introduced as shown below.
Page 31
⚫ Always use test lines provided by ITECH to connect the equipment. If test lines from other factories are used, please check that the test line can withstand maximum current.
Page 38
User can adjust the power switch directly to turn on or turn off the instrument. The status of Power switch is as follows. The switching knob of the IT7900P series power supply allows the user to turn the power on by 90° clockwise or to turn the power off by 90° counterclockwise.
Page 39
Getting Started Single Phase Mode The meter interface of IT7900P series power supply is shown as follow. Status bar Voltage setting&meter value Frequency setting&meter value Display area of measuring data Three Phase Mode The meter interface of IT7900P three phase mode is shown as follow.
Page 46
Source mode. 5.1 full 4-Quadrant output character The IT7900P series represent the newest generation of programmable, full four- quadrant grid simulators with full 100% of current rating in both source and sink mode, and provides energy recovery capability.
Page 47
5.3 Select the Output Mode The IT7900P series has four output modes: AC, DC, AC+DC, DC+AC. It not only provides pure AC/DC output, but also can use AC+DC and DC+AC output modes to realize "AC output plus DC bias" And "DC output waveform with ripple", which cover a wider range of applications.
Page 48
5.3.1 AC Output Mode If the output mode select to AC Mode, the instrument will simulate AC power supply. The default set of IT7900P series power supply is AC Mode. Set the output parameters of the power supply in the main interface, including the output voltage, output frequency.
Page 50
The Vac setting range is 10% of rated voltage. 5.4 Current Limit Mode and Power Limit Mode The IT7900P series power supply defaults to constant voltage CV output mode. The output voltage can be set in main interface. When the actual current value is higher than the setting current limit value, power supply works in current limit mode, and output voltage will be reduce.
Page 54
Voltage Source Mode Operation 5.6 Professional Anti-islanding Test Mode The IT7900P series provide a professional anit-islanding test mode. Users can adjust RLC parameters or configure the parameters of active power and reactive power to simulate islanding status between inverter and load when the main...
Page 56
5.8 Full 4-Quadrant Power Amplifier The IT7900P series regenerative grid simulator can be used as a power amplifier to complete power hardware in the loop (PHIL) applications for microgrids, energy storage and new energy vehicles. The digital I/O or a standard suite of analog signal can be input via an external analog interface (optional) and then amplified without distortion to a real power waveshape.
Page 62
5.12.3 Import/Export List file Import List file IT7900P series support import list file function, The user can finish the editing of List file in Excel and import it into the software. This function simplifies the List file edit and facilitates user operation.
Page 66
Users can edit a custom harmonic waveform file in .csv format and import it into the instrument. User defined harmonic waveform template files can be obtained by contacting ITECH, or an empty file can be exported directly from the instrument.
Page 68
Index/fval: Data points and detailed parameter values. 5.15 Voltage Sampling The IT7900P series instruments can be used as data sampling devices to collect voltage variation signals from other instrument. With this function, users can realize the acquisition of the actual grid voltage change state of the DUT, and then use the import function to reproduce the grid state.
Page 72
Voltage Source Mode Operation 5.17 Polyphase Function The IT7900P series power supplies implement the frequency-locked and phase- locked function between power supplies through the digital IO interface or System bus interface, which achieve 6 phase& 12 phase power output. This power supply provides two ways to achieve multi-phase functionality: One is to connect the System bus interface between instruments directly ⚫...
Page 76
Otherwise the second unit cannot turn on the output normally. 5.18 Standard IEC Regulations IT7900P series AC/DC power supplies provide standard test curves in accordance with IEC 61000-4-11/4-13/4-14/4-17/4-28/4-29 regulations. It can be invoked directly by the user when testing IEC compliance tests.
Page 83
700V. And the output mode can be set to AC/AC+DC. 6.2 Select the Output Mode The IT7900P series has four output modes: AC, DC, AC+DC, DC+AC. It not only provides pure AC/DC output, but also can use AC+DC and DC+AC output modes to realize "AC output plus DC bias"...
Page 85
700V, the input mode can be set to AC/DC. 7.2 Select the Input Mode The IT7900P series load mode supports AC input mode and DC input mode. The user should set the specific input mode according to the desired application.The input mode is selected in the system menu.
Page 86
If the input mode select to DC Mode, the instrument will simulate DC load. 7.3 AC Load Function IT7900P series electronic load according to the setting parameters can simulate the AC electronic load. The users can select the load mode in system menu.
Page 101
7.6 Waveform Selection The user can set the input waveform in the config menu of IT7900P series load. Eight input waveforms below are available, user can select the waveform in Config->Waveform menu.
Page 111
7.12.3 Import/Export List file Import List file IT7900P series support import list file function, The user can finish the editing of List file in Excel and import it into the software. This function simplifies the List file edit and facilitates user operation.
Page 116
Delete: select a row and click Delete. Clean: delete all of data Back: return back upper menu. 7.15 Protection Function IT7900P series load supports comprehensive protection. Press [Shift]+[Config] (Protect) and enter to Protect configure menu, where you can set the following protection. Protect auto clear(UV&FE...
Page 137
Press [Enter] to recall the parameters. 8.6 Screen Capture Function IT7900P series power supply has the screen capture function. Insert the USB equipment into the USB interface of the front panel, and press [Print] on the front panel to capture and save the current screen into the USB disk.
Page 138
System-Related Functions 8.8 Query the System Log The IT7900P series power supply provides the system operation Log query function. On the Menu interface of the front panel of the instrument, click Log or directly press Shift +1[Log] to enter the Log query interface. You can view historical system operation records on this screen.
Page 144
The wiring method is shown in the figure below. 8.11 Remote Measurement Function The IT7900P series power supply supports two connection methods: Local measurement and Remote sensing. The remote sensing is used for maximizing measurement accuracy. (Refer to 2.4 Connecting Test Lines).
Page 147
8.13 Analogue Function (Ext-Program) (Optional) The interface expansion slot provided on the rear panel of the IT7900P series. This function is not standard with the instrument and is optional for users. When the interface card selected by the user is RS232+Analog interface (IT- E177), the analog interface can realize the external analog function.
Page 151
This chapter describes the characteristics and operations of the basic metering function of IT7900P series source. IT7900P series source has rich functions of basic metering of electric energy and can accurately measure the parameters such as Vrms, Irms, Ipeak, Idc, CF,...
Page 152
DC current 9.2 Oscilloscope Mode IT7900P series source has the function of displaying the waveform based on sampling data. The user can select to display or hide the voltage and current waveform of the input unit. Only the necessary waveform is displayed, which can facilitate observation.
Page 154
10us ⚫ Both: Post and Raw, record two data file. 9.3 Harmonic measurement IT7900P series source can display harmonic parameters in the list or bar chart form to make the analysis of test result clear. 9.3.1 Harmonic Measurement Press key on the front panel, and the following initial interface of harmonic measurement will appear.
Page 164
1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380VLL/50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH. IT7906P-350-90 Input parameters(AC Input)...
Page 170
Model IT7908P-350-90 High Performance Programmable AC Power Supply Input parameters 3 phase 3wire + ground(PE) Wiring connection 8.1kW MAX. @( 200~220 )±10% Input Line voltage 8.1kW MAX. @( 380~480 )±10% Input <28.7A(per phase)@200Vac,3∅input Line current <15.3A(per phase)@380Vac,3∅input AC Input <12.2A(per phase)@480Vac,3∅input Apparent power <10 Frequency...
Page 171
Max. power Channel power Per Channel 2.7k Max. power Max. Power 5.4k (reverse phase) (reverse phase ) Max. Power Total power 8.1k (1phase/multichannel ) <0.05% F.S. Line regulation DC,16Hz~500Hz <0.05% + 0.05% F.S. Load regulation 500.01Hz~2.4kHz <0.05% + (0.1%*kHz) F.S. 16Hz~100Hz <0.5% Voltage stability...
Page 172
CR Mode 0.334~388.88 Ω 1phase Range 1.002~1166.6 Ω reverse phase 3phase 1.002~1166.6 Ω Resolution 0.001 Ω <0.4%+0.4%F.S. Accuracy AC Mode Circuit Emulation(CE)-Parallel rlc 1phase 0.334~388.88 R Range reverse phase 1.002~1166.6 Ω 3phase 1.002~1166.6 1~2000 1phase L Range reverse phase 3~2000 3~2000 3phase 1phase...
Page 173
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. All the above parameters are subject to change without prior notice from ITECH.
Page 174
Model IT7909P-350-90 High Performance Programmable AC Power Supply Input parameters(AC Input) Wiring connection 3 phase 3wire + ground(PE) ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <33 AC Input Apparent power <11.1 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 175
Current setting multichannel/reverse -30~30 Range 1phase -90~90 DC Output Resolution 0.01 <0.1% + 0.2% F.S. Accuracy Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power (1phase/multichannel ) Line regulation <0.05% F.S.
Page 176
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution 0.01 DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 150.01Hz~500Hz <0.2% + 0.3% F.S. Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power (1phase/3phase)...
Page 177
Emulation(CE)-Rectifier single phase rlc 1phase 0.334~388.88 R Range Ω reverse phase 1.002~1166.6 3phase 1.002~1166.6 0.1~2000 1phase L Range reverse phase 0.3~2000 3phase 0.3~2000 1phase 0.001~9900 C Range reverse phase 0.001~3300 0.001~3300 3phase 1phase 0~388.88 Range Ω reverse phase 0~1166.6 3phase 0~1166.6 0~499.924 1phase...
Page 178
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 179
Model IT7912P-350-90 High Performance Programmable AC Power Supply Input parameters(AC Input) Wiring connection 3 phase 3wire + ground(PE) ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <29 AC Input Apparent power <14.8 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 180
Current setting multichannel/reverse -30~30 Range 1phase -90~90 DC Output Resolution 0.01 <0.1% + 0.2% F.S. Accuracy Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power (1phase/multichannel ) Line regulation <0.05% F.S.
Page 181
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution 0.01 DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 150.01Hz~500Hz <0.2% + 0.3% F.S. Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power (1phase/3phase)...
Page 182
Emulation(CE)-Rectifier single phase rlc 1phase 0.334~388.88 R Range Ω reverse phase 1.002~1166.6 3phase 1.002~1166.6 0.1~2000 1phase L Range reverse phase 0.3~2000 3phase 0.3~2000 1phase 0.001~9900 C Range reverse phase 0.001~3300 0.001~3300 3phase 1phase 0~388.88 Range Ω reverse phase 0~1166.6 3phase 0~1166.6 0~499.924 1phase...
Page 183
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 184
Model IT7915P-350-90 High Performance Programmable AC Power Supply Input parameters(AC Input) Wiring connection 3 phase 3wire + ground(PE) ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <34 AC Input Apparent power <17.4 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 185
Current setting multichannel/reverse -30~30 Range 1phase -90~90 DC Output Resolution 0.01 <0.1% + 0.2% F.S. Accuracy Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power (1phase/multichannel ) Line regulation <0.05% F.S.
Page 186
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution 0.01 DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 150.01Hz~500Hz <0.2% + 0.3% F.S. Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power (1phase/3phase)...
Page 187
Emulation(CE)-Rectifier single phase rlc 1phase 0.334~388.88 R Range Ω reverse phase 1.002~1166.6 3phase 1.002~1166.6 0.1~2000 1phase L Range reverse phase 0.3~2000 3phase 0.3~2000 1phase 0.001~9900 C Range reverse phase 0.001~3300 0.001~3300 3phase 1phase 0~388.88 Range Ω reverse phase 0~1166.6 3phase 0~1166.6 0~499.924 1phase...
Page 188
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 189
Model IT7930P-350-180 High Performance Programmable AC Power Supply Input parameters(AC Input) 3 phase 3wire + ground(PE) Wiring connection ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <67 AC Input Apparent power <34.8 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 190
Current setting -60~60 multichannel/reverse Range 1phase -180~180 DC Output Resolution 0.01 Accuracy <0.1% + 0.2% F.S. Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power (1phase/multichannel ) Line regulation <0.05% F.S.
Page 191
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution 0.01 DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 <0.2% + 0.3% F.S. 150.01Hz~500Hz Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power (1phase/3phase)...
Page 192
Emulation(CE)-Rectifier single phase rlc 0.167~194.44 1phase R Range Ω reverse phase 0.501~583.32 3phase 0.501~583.32 1phase 0.05~2000 L Range reverse phase 0.15~2000 3phase 0.15~2000 1phase 0.001~19800 C Range reverse phase 0.001~6600 3phase 0.001~6600 1phase 0~194.44 Range Ω reverse phase 0~583.32 3phase 0~583.32 1phase 0~499.924...
Page 193
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 194
Model IT7945P-350-270 High Performance Programmable AC Power Supply Input parameters(AC Input) 3 phase 3wire + ground(PE) Wiring connection ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <100 AC Input Apparent power <52.2 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 195
Current setting -90~90 multichannel/reverse Range 1phase -270~270 DC Output Resolution 0.01 Accuracy <0.1% + 0.2% F.S. Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power (1phase/multichannel ) Line regulation <0.05% F.S.
Page 196
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution 0.01 DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 <0.2% + 0.3% F.S. 150.01Hz~500Hz Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power (1phase/3phase)...
Page 197
Emulation(CE)-Rectifier single phase rlc 0.112~129.62 1phase R Range Ω reverse phase 0.336~388.86 3phase 0.336~388.86 1phase 0.03~2000 L Range reverse phase 0.1~2000 3phase 0.1~2000 1phase 0.001~29700 C Range reverse phase 0.001~9900 3phase 0.001~9900 1phase 0~129.62 Range Ω reverse phase 0~388.86 3phase 0~388.86 1phase 0~499.924...
Page 198
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 199
Model IT7960P-350-360 High Performance Programmable AC Power Supply Input parameters(AC Input) 3 phase 3wire + ground(PE) Wiring connection ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <133 AC Input Apparent power <69.6 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 200
Current setting -120~120 multichannel/reverse Range 1phase -360~360 DC Output Resolution Accuracy <0.1% + 0.2% F.S. Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power (1phase/multichannel ) Line regulation <0.05% F.S.
Page 201
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 <0.2% + 0.3% F.S. 150.01Hz~500Hz Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power (1phase/3phase)...
Page 202
Emulation(CE)-Rectifier single phase rlc 0.084~97.222 1phase R Range Ω reverse phase 0.252~291.66 3phase 0.252~291.66 1phase 0.02~2000 L Range reverse phase 0.07~2000 3phase 0.07~2000 1phase 0.001~39600 C Range reverse phase 0.001~13200 3phase 0.001~13200 1phase 0~97.222 Range Ω reverse phase 0~291.66 3phase 0~291.66 1phase 0~499.924...
Page 203
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 204
Model IT7975P-350-450 High Performance Programmable AC Power Supply Input parameters(AC Input) 3 phase 3wire + ground(PE) Wiring connection ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <167 AC Input Apparent power <87 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 205
Current setting -150~150 multichannel/reverse Range 1phase -450~450 DC Output Resolution Accuracy <0.1% + 0.2% F.S. Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power (1phase/multichannel ) Line regulation <0.05% F.S.
Page 206
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 <0.2% + 0.3% F.S. 150.01Hz~500Hz Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power (1phase/3phase)...
Page 207
Emulation(CE)-Rectifier single phase rlc 0.067~77.777 1phase R Range Ω reverse phase 0.201~233.33 3phase 0.201~233.33 1phase 0.02~2000 L Range reverse phase 0.06~2000 3phase 0.06~2000 1phase 0.001~49500 C Range reverse phase 0.001~16500 3phase 0.001~16500 1phase 0~77.777 Range Ω reverse phase 0~233.33 3phase 0~233.33 1phase 0~499.924...
Page 208
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 209
Model IT7990P-350-540 High Performance Programmable AC Power Supply Input parameters(AC Input) 3 phase 3wire + ground(PE) Wiring connection ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <200 AC Input Apparent power <104.4 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 210
Current setting -180~180 multichannel/reverse Range 1phase -540~540 DC Output Resolution Accuracy <0.1% + 0.2% F.S. Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power (1phase/multichannel ) Line regulation <0.05% F.S.
Page 211
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 <0.2% + 0.3% F.S. 150.01Hz~500Hz Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power (1phase/3phase)...
Page 212
Emulation(CE)-Rectifier single phase rlc 0.056~64.814 1phase R Range Ω reverse phase 0.168~194.44 3phase 0.168~194.44 1phase 0.01~2000 L Range reverse phase 0.05~2000 3phase 0.05~2000 1phase 0.001~59400 C Range reverse phase 0.001~19800 3phase 0.001~19800 1phase 0~64.814 Range Ω reverse phase 0~194.44 3phase 0~194.44 1phase 0~499.924...
Page 213
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 214
Model IT79105P-350-630 High Performance Programmable AC Power Supply Input parameters(AC Input) 3 phase 3wire + ground(PE) Wiring connection ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <233 AC Input Apparent power <121.8 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 215
Current setting -210~210 multichannel/reverse Range 1phase -630~630 DC Output Resolution Accuracy <0.1% + 0.2% F.S. Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power 105k (1phase/multichannel ) Line regulation <0.05% F.S.
Page 216
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power 105k (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 <0.2% + 0.3% F.S. 150.01Hz~500Hz Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power 105k (1phase/3phase)...
Page 217
Emulation(CE)-Rectifier single phase rlc 0.048~55.555 1phase R Range Ω reverse phase 0.144~166.66 3phase 0.144~166.66 1phase 0.01~2000 L Range reverse phase 0.04~2000 3phase 0.04~2000 1phase 0.001~69300 C Range reverse phase 0.001~23100 3phase 0.001~23100 1phase 0~55.555 Range Ω reverse phase 0~166.66 3phase 0~166.66 1phase 0~499.924...
Page 218
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 219
Model IT79120P-350-720 High Performance Programmable AC Power Supply Input parameters(AC Input) 3 phase 3wire + ground(PE) Wiring connection ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <266 AC Input Apparent power <139.1 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 220
Current setting -240~240 multichannel/reverse Range 1phase -720~720 DC Output Resolution Accuracy <0.1% + 0.2% F.S. Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power 120k (1phase/multichannel ) Line regulation <0.05% F.S.
Page 221
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power 120k (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 <0.2% + 0.3% F.S. 150.01Hz~500Hz Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power 120k (1phase/3phase)...
Page 222
Emulation(CE)-Rectifier single phase rlc 0.042~48.611 1phase R Range Ω reverse phase 0.126~145.83 3phase 0.126~145.83 1phase 0.01~2000 L Range reverse phase 0.03~2000 3phase 0.03~2000 1phase 0.001~79200 C Range reverse phase 0.001~26400 3phase 0.001~26400 1phase 0~48.611 Range Ω reverse phase 0~145.83 3phase 0~145.83 1phase 0~499.924...
Page 223
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 224
Model IT79135P-350-810 High Performance Programmable AC Power Supply Input parameters(AC Input) 3 phase 3wire + ground(PE) Wiring connection ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <299 AC Input Apparent power <156.5 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 225
Current setting -270~270 multichannel/reverse Range 1phase -810~810 DC Output Resolution Accuracy <0.1% + 0.2% F.S. Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power (reverse phase) (reverse phase ) Max. Power Total power 135k (1phase/multichannel ) Line regulation <0.05% F.S.
Page 226
Per Phase (3phase ) Input power Max. Power (reverse phase ) Max. Power 135k (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 <0.2% + 0.3% F.S. 150.01Hz~500Hz Temperature coefficient <200ppm/℃ F.S. CP Mode Max. Power 135k (1phase/3phase)...
Page 227
Emulation(CE)-Rectifier single phase rlc 0.038~43.209 1phase R Range Ω reverse phase 0.114~129.62 3phase 0.114~129.62 1phase 0.01~2000 L Range reverse phase 0.03~2000 3phase 0.03~2000 1phase 0.001~89100 C Range reverse phase 0.001~29700 3phase 0.001~29700 1phase 0~43.209 Range Ω reverse phase 0~129.62 3phase 0~129.62 1phase 0~499.924...
Page 228
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 229
Model IT79150P-350-900 High Performance Programmable AC Power Supply Input parameters(AC Input) 3 phase 3wire + ground(PE) Wiring connection ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <333 AC Input Apparent power <173.9 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 230
Current setting -300~300 multichannel/reverse Range 1phase -900~900 DC Output Resolution Accuracy <0.1% + 0.2% F.S. Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power 100k (reverse phase) (reverse phase ) Max. Power Total power 150k (1phase/multichannel )...
Page 231
Per Phase (3phase ) Input power Max. Power 100k (reverse phase ) Max. Power 150k (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 <0.2% + 0.3% F.S. 150.01Hz~500Hz Temperature coefficient <200ppm/℃ F.S. CP Mode Max.
Page 232
Emulation(CE)-Rectifier single phase rlc 0.034~38.888 1phase R Range Ω reverse phase 0.102~116.66 3phase 0.102~116.66 1phase 0.01~2000 L Range reverse phase 0.03~2000 3phase 0.03~2000 1phase 0.001~99000 C Range reverse phase 0.001~33000 3phase 0.001~33000 1phase 0~38.888 Range Ω reverse phase 0~116.66 3phase 0~116.66 1phase 0~499.924...
Page 233
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 234
Model IT79165P-350-990 High Performance Programmable AC Power Supply Input parameters(AC Input) 3 phase 3wire + ground(PE) Wiring connection ( 200~220 ) ±10% Line voltage ( 380~480 ) ±10% Line current <366 AC Input Apparent power <191.3 Frequency 45~65 Power factor 0.98 Output parameters(Voltage Source mode)...
Page 235
Current setting -330~330 multichannel/reverse Range 1phase -990~990 DC Output Resolution Accuracy <0.1% + 0.2% F.S. Temperature <200ppm/℃ F.S. coefficient Max. power Channel power Per Channel Max. power Max. Power 110k (reverse phase) (reverse phase ) Max. Power Total power 165k (1phase/multichannel )...
Page 236
Per Phase (3phase ) Input power Max. Power 110k (reverse phase ) Max. Power 165k (1phase/3phase) CC Mode (1phase) Current Range (3phase/reverse) Resolution DC,16Hz~150Hz <0.1% + 0.2% F.S. Accuracy*9 <0.2% + 0.3% F.S. 150.01Hz~500Hz Temperature coefficient <200ppm/℃ F.S. CP Mode Max.
Page 237
Emulation(CE)-Rectifier single phase rlc 0.031~35.353 1phase R Range Ω reverse phase 0.093~106.05 3phase 0.093~106.05 1phase 0~2000 L Range reverse phase 0.02~2000 3phase 0.02~2000 1phase 0.001~108900 C Range reverse phase 0.001~36300 3phase 0.001~36300 1phase 0~35.353 Range Ω reverse phase 0~106.05 3phase 0~106.05 1phase 0~499.924...
Page 238
In the rectifier load mode, the setting range of phase Angle is related to CF. The larger CF is, the larger the range of phase Angle can be set. 1% F.S. for frequencies 150 Hz and less, 5% F.S. for frequencies greater than 150 Hz. Test conditions: 380V /50Hz AC input, 350Vrms/50Hz/full power output. All the above parameters are subject to change without prior notice from ITECH.
Page 242
Inspection and Installation ⚫ LAN Configuration: Reconfigure the LAN parameters; ⚫ Manual: Go to the ITECH official website and view or download the relevant documents. Upload: Performs a system upgrade. ⚫ Click CONNECT to connect the PC with the instrument, then click Select File to select the system upgrade installation package (for example, IT7900P-U-VXXX.itech), and then click UPLOAD performs the upgrade...
Page 246
PV7900P Demo Software(Standard) IT7900 series power supply supporting remote control software, users can directly obtain the software from ITECH agent and install to the PC, to achieve remote control equipment by visualization method, IT9000-PV7900 software can achieve all the instrument panel operation. And the interface is simple and convenient to operate.
Page 247
Appendix Specifications of Red and Black Test Lines ITECH provides you with optional red and black test lines, the user can choose the company's test line for testing. For specifications of ITECH test lines and maximum current values, refer to the table below.
Need help?
Do you have a question about the IT7900P Series and is the answer not in the manual?
Questions and answers