8.11. Status, Error, and SRQ Registers

8.11.1. General Description
This Section describes the structure and operation of the six status, error, and SRQ
registers. The registers can be set or read via the RS-232/RS-485 commands.
Refer to Fig. 8-7 for the Status and Error Registers Diagram.
NOTE: these registers operate in a way that is similar to the IEEE-488 and SCPI
registers (as used by the Genesys™ with the "-IEMD" option), but the structure and
command set is different.
Constant Voltage
Constant Current
No Fault
Fault
Auto Start
Fold Enabled
Spare
Local Mode
Spare
AC Fail
Over Temperature
Foldback (tripped)
Over Volt Prot
Shut Off (rear panel)
Output Off (front panel)
Enable Open
Command Error ("Cnn")
Execution Error ("Enn")
Query Response ("message")
Command Response ("OK")
Status Registers
Condition
Enable
LSB
0
CV
1
CC
2
NFLT
3
FLT
4
0
AST
5
0
FDE
6
0
0
MSB
7
LCL
"STAT?" "SENA xx"
"SENA?"
Fault Registers
Condition
Enable
LSB
0
0
1
AC
2
OTP
3
FLD
4
OVP
5
SO
6
OFF
MSB
7
ENA
"FENA xx"
"FLT?"
"FENA?"
Fig.8-7: Status and Error Registers Diagram
90
83532002 Rev C
Response
messages
Event
CV
CC
NFLT
SRQ
FLT
Messages
0
0
0
LCL
"SEVE?"
Event
0
AC
OTP
FLD
OVP
SO
OFF
ENA
"FEVE?"
One response for every command
or query received.
Serial
TXD
"Inn" and CR
One SRQ when SEVE goes
from all zeroes to any bit set.
Setting more SEVE bits does
not cause more SRQs.
Positive Logic:
0 = No Event
1 = Event Occured