Isolated Programming & Monitoring Connector - TDK-Lambda Genesys User Manual

10kw/15kw programmable dc power supplies
Hide thumbs Also See for Genesys:
Table of Contents

Advertisement

9.3.
Isolated Programming & Monitoring Connector
Refer to Table 9-1 for a detailed description of the rear panel Isolated Programming &
Monitoring connector. To provide the lowest noise performance, it is recommended to use
shielded-twisted pair wiring.
Refer to Fig.9-1 for description of the connector.
Isolated programming plug P/N: MC1.5/8-ST-3.81, Phoenix.
+VPROG_ISO
+IPROG_ISO
GND_ISO
Fig. 9-1: Isolated Programming & Monitoring connector
Table 9-1: Detailed Description of Isolated Programming & Monitoring Connector
Terminal
Signal name
1
SHLD
2
+VPROG_ISO
3
+IPROG_ISO
4
GND_ISO
5
GND_ISO
6
+VMON_ISO
7
+IMON_ISO
8
SHLD
1
2
3
Shield
Function
Shield, connected internally to chassis
of the power supply.
Output Voltage Programming input
Output Current Programming input
Ground for programming signals.
Ground for programming signals.
Output Voltage Monitoring output
Output Current Monitoring output
Shield, connected internally to chassis
of the power supply.
83532002 Rev C
4
5
6
7
8
Range 0-5V/0-10V
IS510 option
0-5V/0-10V
0-5V/0-10V
0-5V/0-10V
0-5V/0-10V
96
Shield
+IMON_ISO
+VMON_ISO
GND_ISO
Range 4-20mA
IS420 option
Chassis ground
4-20mA
4-20mA
Ground
Ground
Ground
Ground
4-20mA
4-20mA
Chassis ground