7.8 STATUS, ERROR AND SRQ REGISTERS

7.8.1 General

This section describes the various status error and SRQ registers structure. The registers can be
read or set via the RS232/485 commands. When using the IEEE option, refer to the user manual
TM
for Genesys
Power Supply IEEE Programming interface.
Refer to Fig.7-7 for the Status and Error Registers Diagram.
Command Error ("Cnn")
Execution Error ("Enn")
Query Response ("message")
Command Response ("OK")
Constant Voltage
Constant Current
No Fault
Fault
Auto Start
Fold Enabled
Spare
Local Mode
Spare
AC Fail
Over Temperature
Foldback (tripped)
Over Volt Prot
Shut Off (rear panel)
Output Off (front panel)
Enable Open

7.8.2 Conditional registers

The fault Condition Register and the Status Condition Register are read only registers that the user
may read to see the condition of the supply. Refer to table 7-8 for description of the Fault Condition
Register bits and Table 7-9 for the Status Condition register bits.
Status Registers
Condition Enable
LSB
0
CV
1
CC
2
NFLT
3
FLT
4
0
AST
5
0
FDE
6
0
0
MSB
7
LCL
"STAT?" "SENA xx"
"SENA?"
Fault Registers
Condition
Enable
LSB
0
0
1
AC
2
OTP
3
FLD
4
OVP
5
SO
6
OFF
MSB
7
ENA
"FENA xx"
"FLT?"
"FENA?"
Fig.7-7: Status and Error Registers Diagram
Response
OR
messages
Event
CV
CC
NFLT
SRQ
FLT
OR
Messages
0
0
Address
0
Changed
LCL
"SEVE?"
OR
Event
0
AC
OTP
FLD
OR
OVP
SO
OFF
ENA
"FEVE?"
58
58
One response for every command
or query received.
Serial
OR
TXD
SRQ = "!nn",
nn = address
One SRQ when SEVE goes
from all zeroes to any bit set.
Setting more SEVE bits does
not cause more SRQs.
Positive Logic:
0 = No Event
1 = Event Occured