Connecting Power Supplies To The Rs-232 Or Rs-485 Bus - TDK-Lambda Genesys User Manual

10kw/15kw programmable dc power supplies
Hide thumbs Also See for Genesys:
Table of Contents

Advertisement

8.4.

Connecting Power Supplies to the RS-232 or RS-485 Bus

8.4.1. Single Power Supply
a) Select the desired interface, RS-232 or RS-485, using the rear panel setup switch
SW1-6 (Section 4.3).
SW1-6 DOWN: RS-232
SW1-6 UP: RS-485
b) Connect the rear panel J3-IN connector to the controller RS-232 or RS-485 Digital
communication port using a suitable shielded cable.
Refer to Figures 8-2, 8-3 and 8-4 for available RS-232 and RS-485 cables.
13
1
Sockets
Fig.8-2: RS-232 cable with DB25 connector (P/N: GEN/232-25)
5
1
Sockets
Fig.8-3: RS-232 cable with DB9 connector (P/N: GEN/232-9)
5
1
Sockets
Fig.8-4: RS-485 cable with DB9 connector (P/N: GEN/485-9)
L=2m typ.
DB-25 CONNECTOR
8 PIN CONNECTOR
NAME
PIN NO.
PIN NO.
1
SHIELD
2
TX
8
3
RX
7
7
1
SG
L=2m typ.
DB-9 CONNECTOR
8 PIN CONNECTOR
PIN NO.
NAME
PIN NO.
SHIELD
HOUSING
HOUSING
2
RX
7
3
TX
8
5
1
SG
8 PIN CONNECTOR
DB-9 CONNECTOR
PIN NO.
NAME
PIN NO.
HOUSING
HOUSING
SHIELD
-
9
TXD
6
+
3
8
TXD
1
SG
1
-
5
5
RXD
4
4
+
RXD
79
83532002 Rev C
REMARKS
NAME
SHIELD
TWISTED
RX
PAIR
TX
SG
REMARKS
NAME
SHIELD
TWISTED
TX
PAIR
RX
SG
L=2m typ.
REMARKS
NAME
SHIELD
-
RXD
TWISTED
+
RXD
PAIR
SG
-
TXD
TWISTED
+
TXD
PAIR
8
1
8
1
8
1

Advertisement

Table of Contents
loading

Table of Contents