In a LAN system, each Power Supply can be controlled using the optional LXI certified
LAN interface (factory installed).
1.2.4. Control via the Serial Communication Port
The following parameters can be programmed via the serial communication port:
a) Output voltage setting.
b) Output current setting.
c) Output voltage measurement.
d) Output On/Off control.
e) Output current measurement.
f) Foldback protection setting
g) Over-voltage protection setting and readback.
h) Under-Voltage limits setting and readback.
i)
Power Supply start up mode (last setting or safe mode).
1.2.5. Analog Voltage Programming and Monitoring
Analog inputs and outputs are provided at the rear panel for Remote Analog control of
the Power Supply. The Output voltage and the Output current limit can be programmed
by analog voltage or by resistor, and can be monitored by analog voltage. The Power
Supply output can be remotely set to On or Off and analog signals monitor the proper
operation of the Power Supply and the mode of operation (CV/CC).
1.2.6. Parallel Operation
TM
Genesys
power supplies of the same Output voltage and Output current rating can be
paralleled in Master-Slave configuration with automatic current sharing to increase
user-available Output power available.
1.2.7. Output Connections
Output connections are made to rear panel via bus-bars up to Vout = 300V and via stud
terminals for models with Vo > 300V. Either the positive or negative terminal may be
grounded or the entire Output may be floated. All models shall not float outputs more
than +/- 600VDC above/below Chassis ground. Contact the factory for assistance with
higher float voltage applications.
Local or remote sense may be used. In remote sense, the voltage drop on the load
wires should be minimized. Refer to the Power Supply specifications of Section 2 for
the remote sense maximum voltage drop value.
1.2.8. Cooling and Mechanical Construction
TM
The Genesys
must be taken to allow free airflow into the Power Supply via the front panel and out of
the Power Supply via the rear panel.
Observe all torque guidelines within this User's Manual. Over-torqueing
hardware may damage the unit or accessories. Such damage is not covered
Power Supply Series is cooled by internal fans. During installation, care
CAUTION
under Manufacturer's Warranty.
24
83532002 Rev C