TDK-Lambda Genesys User Manual page 76

10kw/15kw programmable dc power supplies
Hide thumbs Also See for Genesys:
Table of Contents

Advertisement

Programmed Voltage to zero.
 Programmed Current to zero.
 UVL to zero volts
 OVP to its maximum value
 AST OFF
 OUT OFF
 Foldback Protection OFF
 Locked Front Panel
NOTE
With local sensing it is important to minimize the wire length and resistance. Also,
the positive and negative wire resistance should be as close as possible to each
other to achieve current balance between the power supplies.
Figure 6-7: Parallel Connection with Local Sensing (Two-Wire Method)
Figure 6-8: Parallel Connection with Remote Sensing (Two-Wire Method)
CAUTION
Make sure that the connection between –V terminals is reliable to avoid
disconnection during operation. Disconnection may cause damage to the power
supply.
70
83532002 Rev C