Emc; Safety - TDK-Lambda Genesys User Manual

10kw/15kw programmable dc power supplies
Hide thumbs Also See for Genesys:
Table of Contents

Advertisement

2.12. EMC

1. ESD
2. Fast transients
3. Surge immunity
4. Conducted immunity
5. Radiated immunity
6. Power Frequency Magnetic Field
7. Conducted emission
8. Radiated emission
Note: EMC Approval for:
Vout < 30V @ 208VAC/400VAC
30V ≤ Vout ≤ 600V @ 208VAC/400VAC/480Vac

2.13. Safety

1. Applicable Standards
2. Insulation resistance
CE Mark
---
EN61000-4-2 (IEC 1000-4-2): Air-disch. +/-8kV, contact disch. +/-4kV
---
EN61000-4-4 (IEC 1000-4-3): +/-2kV: AC Power, 2kV: DC Output
---
EN61000-4-5 (IEC 1000-4-5): 1kV line-to-line, 2kV line-to-ground
---
EN61000-4-6 (IEC 1000-4-6): 10Vrms
---
EN61000-4-3 (IEC 1000-4-3): 10V/m
---
EN61000-4-8: 30A/m
---
EN55011A, FCC part 15J-A
---
EN55011A, FCC part 15J-A
---
UL/cUL 60950-1, EN60950-1 recognized (CB Scheme)
All Outputs are Hazardous.
For Vout ≤ 400VDC: IEEE, LAN, IS510 or IS420 are SELV.
CE mark for all inputs (208VAC, 400VAC, 480VAC).
---
100Mohm at 500Vdc, 25°C, 70% Relative Humidity