Date of Expiry - This is the date of expiry of the current CHIRPS Configuration File. A new file with
the following format must be loaded.
Day of Month
Month
Last 2 digits of Year
Number of Sessions - This is the number of sessions that CHIRPS will run in the range of 0000 to
9999. After entry the value decrements by one until it reaches 0001. CHIRPS will then cease to run.
If the number is initially set to zero, CHIRPS will run for an indefinite number of times.
HHU Identification - This is an eight digit identifier determining the type of HHU that CHIRPS is
running on.
File Size - The file size should always be set to 12
Comms Port - If the first three characters are set to COM. then the fourth character is interpreted as
the comms port (e.g. COM1) which is the default value.
Timings - CHIRPS timing protocols should be set to the following values and not changed.
Timing 1
Timing 2
Timing 3
Timing 4
Load Default - The default file is identical to the Configuration File and can be loaded in case
CHIRPS has been corrupted.
A new default file can be generated by saving the data and re-saving the file HHU.CFG to HHU.DEF.
Click System Exit to return to the Power Master Unit.
( 2 Characters)
( 2 Characters)
( 2 Characters)
1600
3000
0200
0100
01-31
01-12
00-99
Power Master Unit