Error messages when entering values ....................14 3 Working with enSuite ..........................15 Setting up the communication link to the EK280 via optical interface ..........15 Setting up the communication link to EK280 via a modem ............... 15 Setting up the communication link to EK280 via a network (TCP/IP) ..........16 Setting up a direct communication link to EK280 ................
Page 4
EK280 Application Manual Warning input inactive ........................31 Information input active ........................31 Information input inactive ........................31 Time-synchronous input ........................32 Additional metering input (Input 3) ....................32 5.6.1 Archive for the additional metering input (Input 3)..............33 6 Outputs ............................... 34 Connection of outputs ........................
Page 5
EK280 Application Manual 7.5.3 Connection configuration status "StCon" ................118 7.5.4 Status of remote terminal "SDst" .................... 119 7.5.5 GSM modem status "StM" ...................... 120 Registration of the GSM receiving level in a flexible archive ............120 7.6.1 Connection..........................120 7.6.2...
Avoid improper battery use. Avoid contact with live parts in the EK280 version with internal power supply. Should any instructions in the Application Manual conflict with those given in the Operating Instructions, follow the instructions in the Operating Instructions.
EK280 Application Manual 2 EK280 Operation and Display 2.1 Display configuration 2.1.1 "Main" main display With the calibration lock open, "Main" on the "Ctrl." display tab allows you to select different views and contents for the "Main" tab: "Main" Description...
Connect a PC or laptop with enSuite installed to the EK280 optical interface using the connection cable. Start enSuite and set up the communication link to the EK280. (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) ...
EK280 Application Manual 2.2 EK280 archives display A comprehensive description of the archive can be found in Chapter 9) To display the contents of an archive, move the cursor to the archive header and press the ENTER or key.
EK280 Application Manual Display Description All values within an It is not possible to calculate a valid progress index due to a data error in the archive row flash. current archive row. The data error is detected via checksum (CRC).
EK280 Application Manual 2.3 Context menu The context menu allows you to quickly access specific commands in the various displays. The context menu is accessed using the key. Figure 2: displayed context menu 2.3.1 Jump to main display ("Goto Main") The main display ("Main"...
The counter of the EK280 can be set once in a similar way to that of the gas counter while the administrator lock is open for recording the volume in practice. When the calibration lock is open it is always possible to set the volume and this can also be done directly via the operational volume (tab "Serv."...
A one-off setting of the volume counter is possible from software version 2.20 while the administrator lock is open. The quantity converter EK280 offers the possibility of adjusting the standard volume counter once during commissioning of the unit while the administrator lock is open. Setting the volume is always possible while the calibration lock is open and can also be carried out directly via Standard Volume (tab "Serv."...
(Vb new value) will be set to default values. 2.5 Parameterize display contrast The display contrast of the EK280 can be adjusted to suit the surrounding conditions. Open the administrator lock as described in the EK280 operating manual. ...
EK280 Application Manual 2.6 Error messages when entering values If a value has been entered incorrectly via the keyboard, input error messages will be displayed. Figure: --x-- where x = error code according to the following table Code Description The archive is empty. No values have been entered.
The enSuite parameterization program can be downloaded for free at www.elster.com. Insert the optical read head into the ring on the front panel of the EK280 and connect the other end to a COM or USB port on your PC or laptop.
3.3 Setting up the communication link to EK280 via a network (TCP/IP) Requirement: A communication link between enSuite and the EK280 (see chapter 7). Ensure your PC or laptop is connected to the LAN. The EK280 must be connected to the same network. ...
EK280 Application Manual 3.6 Send parameter file Prerequisite: A communication link between enSuite and the EK280 via optical interface, modem or network (TCP/IP) has been set up (see chapters 3.1 to 3.3). Select "Navigation" on the left-hand side. ...
4.1 LF Pulse generator (reed contact) 4.1.1 Connection Danger! For EK280 with internal power supply, the mains voltage must be switched off before opening the housing, ensure it is not turned back on and verify that there is no voltage. Pulse generator (Reed contact) ...
HF Pulse generator (Namur) Connect the gas meter's high frequency pulse generator (Namur) to terminal "DE1" of the EK280. Release the input 1 (terminal "DE1") calibration seals. 4.2.2 Parameterization Parameterization is carried out via the keyboard on the EK280.
Wait until the "Auto-Encoder" display is updated with a new value. This can take up to a minute as the EK280 activates and test all known encoder protocols consecutively. On successful detection the EK280 displays the label "Vo" on the meter reading of the gas meter: ...
Page 23
1 instead of "VmG" (total operating volume), then use the "enSuite" parameterization program to send the following parameter file to the EK280 (see chapter 3.6 "Send parameter file", page 17): After loading the WPP file, the measurement period archive, the daily archive and monthly archives 1 and 2 are deleted! ...
4.4 HF pulse input with automatic conversion The EK280 can only count pulses from a high frequency pulse generator via an external power supply, and not battery power. To ensure uninterrupted gas volume measurement, the EK280 can be configured so that it switches to a low frequency pulse generator in the event of failure of the external power supply.
Application Manual 4.4.2 Parameterization Parameterization is here described with reference to the EK280 keyboard and the above mentioned example. Alternatively, parametrization can be carried out using the enSuite program. The paths which are subsequently described can be found in enSuite under "Parameterize...
Connect the second low frequency pulse generator (LF reed contact) to terminal "DE2". 4.5.2 Parameterization To program input 2 for the pulse comparison with input 1, send the following parameter file to the EK280 using the parameterization program "enSuite" (see chapter 3.6 "Send parameter file", page 17): ...
Page 27
The default is 4 ("maximum number of disturbance pulses") within a 4000 pulse ("pulse window per disturbance pulses"). This setting can be updated using the EK280 keypad or with enSuite: On the "Serv." display tab of the EK280 keypad: Data book >...
2 (Q2) will be archived in flexible archive 12. The maximum record size is 5000 rows. The HF probe of the gas meter (A1S / A1R) must be connected to input 2! The EK280 must be mains supplied in order to be able to record the pulses from the HF probe! 4.6.1 Pulse generator connection...
4.6.2 Parameterization For programming Input 2 as the measuring input for HF acquisition, use the parameterization program "enSuite" to send the following parameters to EK280 (see Chapter 3.6, Page 17): EK280_xvx. - Application: Qm monitoring (Q2-HF) and storage in Archive 12 (*) After loading of the file, it is also still necessary to set the pc value for input 2 (HF) and the limit,above which any load excess is to be recorded.
HF transmitter on input 2. As a result, the HF output of the EK280 can respond more quickly to input fluctuations. An external power supply for the EK280 is essential for this purpose, as is the provision of HF pulses by the gas meter (A1S/A1R).
Page 31
EK280 Application Manual Setting the high frequency pulse generator's input mode: Press the key until "Md.I2" is displayed. Press the ENTER button. The set value flashes. Repeatedly press one of the or arrow keys until the text ...
Time-synchronous: With a valid input signal the EK280 clock can be synchronized (set) to the full hour. Pulse comparison . A user-defined variation between two pulse generators generates a warning message in the momentary status and status register. Description: See Chapter 4.5 ...
The status message can then be used, for example to create an archive entry or to switch an output. To program an input as an active information input, send the relevant parameter files from the following to the EK280 using the parameterization program "enSuite" (see chapter 3.6 "Send parameter file", page 17): ...
The inputs are already programmed as pulse inputs at the factory so that a conversion is usually superfluous. To program input 3 back to metering, send the following parameter file to the EK280 using the parameterization program "enSuite" (see Chapter 3.6 "Send parameter file", page 17): ...
For reliable activation of input 3 as a metering input and for recording in the flexible archive, you transmit the following parameter file to EK280 by means of the "enSuite" parameterizing program in the sub folder "EK280 / "V2xx"-/applications (see Chapter 3.6 "Send parameter file", page17 ): ...
For EK280 with internal power supply, the mains voltage must be switched off before opening the housing, ensure it is not turned back on and verify that there is no voltage. Connected device e.g. DL230 Connect the device to one of the desired digital outputs (terminals "DA1" to "DA4") on the EK280.
Output 4 Md.O4 The low-frequency pulse output of the EK280 can be operated with active or inactive logic. The output mode must be programmed accordingly for this purpose (see below). Press the ENTER button. The actual parameterized value flashes.
Page 38
Application Manual Setting up period length and pulse duration Parametrization of the period length and the pulse duration via the EK280 keyboard is only possible with software version 2.20 or later. Older software versions may be programmed using enSuite via "Parameterize...
Outputs Output 4 Md.O4 The status outputs of the EK280 can be operated with active or inactive logic. The output mode must be programmed accordingly for this purpose (see below). Press the ENTER button. The actual parameterized value flashes.
Page 40
= Warning gray = Information. Consequently every alarm would lead to output switching. Press "OK" to accept the setting. After confirmation, the speed button “Transfer changes to device" in enSuite must be used to transmit the values finally to the EK280.
Outputs Output 4 Md.O4 The time-synchronized outputs of the EK280 can be operated with active or inactive logic. The output mode must be programmed accordingly for this purpose (see below). Press the ENTER button. The actual parameterized value flashes.
1, an FE260 must be used for isolation of the outputs and the power supply in the event of explosion. If output 3 of the EK280 is also to be routed through the FE260 as an F output, this is only possible with an FE260 built later than April 2014.
EK280 Application Manual 6.5.3 Parameterization Parameterization of the EK280 must be effected with the "enSuite" software, as this is the only way of setting all necessary parameters. The parameters to be set will be found under the following menu headings.
When connecting the outputs to a customer system (e.g. PLC) galvanic separation of both systems is strongly recommended. Especially when using or connecting the EK280 to a hazardous area (hazardous area 1), an external isolation amplifier (permitted for use in hazardous areas) or usage of the FE260 is required.
EK280 Application Manual In particular, when connecting more than one output to a PLC, it must be taken into consideration that under normal operating conditions all 4 outputs have a common earth. Inputs on a PLC often have a common "plus" contact so that all outputs can be switched in parallel.
(galvanic separation) Galvanic separation of the outputs is not relevant with regard to hazardous areas. If using the EK280 in hazardous area 1 then a permitted, external separator is required which is suitable for use in hazardous areas. An electrically isolated output only requires electricity provided that the output is active (switched on).
Unplug the modem from the power supply to avoid damage to the modem and SIM card. This applies also to an EK280 with power supply which is disconnected from the mains, in case a back-up battery supply is connected!
Page 48
Connect the modem plug back to the power supply. In case of an EK280 with an internal power supply, the mains voltage must not be switched back on again at this point, otherwise damage to the internal power supply and the internal modem may take place.
EK280 via the modem. There are two available time windows, which operate on EK280 battery power only and for versions of the EK280 with power supply there are two more, which operate only on mains voltage. Make the battery power time windows only as long and frequent as absolutely necessary. Each time window reduces the EK280's battery life.
Page 50
The editable time window is not directly reflected in the forecast of the remaining battery life of the batteries" BatR" of the EK280. Therefore the forecast battery life is not changed if the time window is changed. Past time windows and data transfers are however used in the remaining battery capacity "BatRK"...
Page 51
The test time window only needs to be open if none of the time windows 1 to 4 are open. If the communication link to the EK280 via the optical interface is not set up, it must be created. (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) ...
GSM operation, as explained in chapter 7.1.2. Here the GPRS Modem in the EK280 functions as a TCP-Server and may be addressed by a TCP client that is listed in its readout software through a static IP address. To allocate a static IP to the modem during the setup of the GPRS session, they must (together with their GPRS provider) maintain a virtual private network (VPN) which must be enabled on the SIM used in the modem.
Page 53
In the base configuration now displayed you can define time windows, during which data can be retrieved cyclically from the EK280 via the modem. There are two available time windows, which operate on EK280 battery power only and for versions of the EK280 with power supply there are two more, which operate only on mains voltage.
Page 54
The test time window only needs to be open if none of the time windows 1 to 4 are open. If the communication link to the EK280 via the optical interface is not set up, it must be created. (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) ...
7.1.4.3 Opening the customer lock In order for ComFTP to read data from the EK280 and save it on the server, at least one EK280 lock must be permanently open. For this purpose it is recommended to use the customer lock, as this contains the least write permissions and therefore avoids the risk of unauthorized parameter updates.
Page 56
In the base configuration now displayed you can define time windows, during which data can be retrieved cyclically from the EK280 via the modem. There are two available time windows, which operate on EK280 battery power only and for versions of the EK280 with power supply there are two more which operate only on mains voltage.
Page 57
The test time window only needs to be open if none of the time windows 1 to 4 are open. If the communication link to the EK280 via the optical interface is not set up, it must be created. (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) ...
Page 58
Once the application has been configured, you can check the data transfer to the FTP server using a suitable FTP client (i.e., "Filezilla"). Data should now be automatically transferred from EK280 at the intervals programmed in the ComFTP to the server.
Then wait a minute, for any communications activity in progress on the EK280 to be safely stopped. b) Send parameter file Send the following parameter file to the EK280 (see Chapter 3.6, "Send parameter file", page 17): EK280_xvx..
Page 60
ComTSC modem in accordance with Section 7.1.5.3! You may define time windows which allow you to call off data from EK280 via the modem. There are two available time windows, which operate on EK280 battery power only and for versions of the EK280 with power supply there are two more which operate only on mains voltage.
Page 61
"ComTSC". Then press the button "Connect": Having pressed the button "Connect" the dialog box "Settings for application GPRS-TSC" opens. Here you need to enter End device "EK280" and the GPRS provider and enter the TSC login data.
Page 62
EK280 Application Manual The input of the TSC server address may be in the form of a DNS or the form of an IP address. A secondary TSC server may be entered as an option. When entering the TSC port name and TSC password, appropriate use of lower case and...
Page 63
The test time window only needs to be open if none of the time windows 1 to 4 are open. If the communication link to the EK280 via the optical interface is not set up, it must be created. (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) ...
Page 64
Test retrieval via the modem Set up the modem communication link between enSuite and EK280. (see chapter 3.2 "Setting up the communication link to EK280 via a modem", page 15) For a test retrieval using a conventional GSM-CSD modem connection when in "Tools –...
7.1.6 Replacing the antenna Danger! For EK280 with internal power supply, the mains voltage must be switched off before opening the housing, ensure it is not turned back on and verify that there is no voltage. If reception via the internal modem is too poor, it is possible to replace the mounted short antenna with SMA connection.
Page 66
To check the function, you may now open a time window for testing and check the GSM signal quality on the EK280 display (see Section 7.1.2.2 "Checking GSM field strength", page 48) and for a test call off with enSuite (see Section 7.1.2.3.
EK280 Application Manual 7.1.7 Upgrading an internal modem For the installation of an internal GSM/GPRS modem in the EK280 at a later date, please proceed as follows. ATTENTION: The permitted modem assembly (73021257 or 73022761) depends on the area in which it is...
Page 68
EK280 Application Manual Lead the protective earth wire laterally out of the bore (see illustration)! If this is not done, the antenna cannot be pushed into the correct position. Fasten the antenna by tightening the cable gland (see illustration.) While tightening, hold the antenna from the inside against the cable gland.
Page 69
To check the function, you may now open a time window for testing and check the GSM signal quality on the EK280 display (see Section 7.1.2.2 "Checking GSM field strength", page 48) and for a test call off with enSuite (see Section 7.1.2.3. Retrieving data with enSuite", page 49).
Ethernet). The name of the parameter file to be used is given further down in the appropriate section. For the connection of the EM260 to EK280, an 8 core cable needs to be used; this is included with the EM260 as supplied.
In the base configuration now displayed you can define time windows, during which data can be cyclically retrieved from the EK280 via the modem. Time windows 5 and 6 are reserved for EK280 operation with an EM260. Redundant time windows can be deactivated by setting the time window start and end to the same value.
Page 72
7.2.2.2 Parameterization of the analog PSTN modem integrated into EM260 If the order for the EM260 stated that it was to be operated connected to an EK280, the parameterization of the EM260 was already effected at the factory, so you may skip this section.
Page 73
Close the housing of the WM260. Switch on the mains power supply of the EM260 again. The plug symbol in the Main Menu of the EK280 shows the external supply. 7.2.2.3 Retrieving data with enSuite See Section 7.1.2.3 "Retrieving data with enSuite", page 49)
All the values listed in enSuite under "Parameters" can be found on the “Serv." display tab of the EK280 under the same path. The EK280 will only work with an EM260 model from year 2009 with a Baud rate of 19200. EM260 devices before 2009 need to be operated with a Baud rate of 9600.
Page 75
EK280 to the Ethernet adapter. Wait for approx. 1 minute, so that the initialization string can be reliably sent from EK280 to the Ethernet card. Attention! Then it is necessary to perform a Reset of the Ethernet card (interrupt the ext. supply voltage provided by EM260 briefly).
Page 76
CAUTION! 230 V alternating current Risk to life! For parameterization of the Ethernet adapter in the EM260 for operation with an EK280 you need the USB parameterization cable with the identification no. 73020481 and the ModemIni V3.50 or later which you can order free of charge from Elster.
Page 77
Push fit the J1 in the uppermost position (see operating instructions for the EM260, Section 10 "Jumper" and photograph on the right). Make sure that the EM260 is connected in accordance with Section 7.2.1 to the EK280. Close housing of EM260...
Page 78
(in the path "Parameters" > "Interfaces" > "Internal modem"), so that the values correctly set in the modem are not reset by the EK280 after opening of the time window or overwritten by incorrect values. 7.2.3.4 Checking accessibility ...
All the values listed in enSuite under "Parameters" can be found on the “Serv." display tab of the EK280 under the same path. The EK280 will only work with an EM260 model from year 2009 with a Baud rate of 19200. EM260 devices before 2009 need to be operated with a Baud rate of 9600.
Page 80
CAUTION! 230 V alternating current Risk to life! Start the ModemIni program (V3.50 or later) and perform the following settings: - terminal device: EK280 - Modem box: EM260 - Modem module: GSM-Modem - PC interface: COMx (the COM interface, to which the parameterization cable is connected) ...
Page 81
On the modem adapter board, push-fit the jumper "Mode" in the position "operation" r.h. position, see photograph). Make sure that the EM260 is connected in accordance with Section 7.2.1 to the EK280. Make sure that a SIM card is inserted into the CSM modem.
Page 82
The test time window only needs to be open if none of the time windows 5 to 6 is currently open. If the communication link to the EK280 via the optical interface is not set up, it must be created. (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) ...
FE260 is ordered (2m, 5m or special length) The individual cores must be taken to the inside of the EK280 through one of the metal unions; the housing of the EK280 needs to be opened up for this purpose.
Page 84
EK280 Application Manual 7.3.1.1 Wiring FE260 230V AC 230V EK280 Uext+ Uext- 7.3.1.2 EK280 jumpers X6: No jumper X5: two jumpers or a jumper on a pin located closer to the on the pins located terminals. furthest from the terminals.
Move the cursor to the "Serv." tab in the EK280's display, then to Interfaces > Terminal interface > GSM & GPRS > PIN key and enter the first PIN digit using the and arrow keys.
Page 86
EK280 Application Manual 7.3.2.2 SIM in GSM/GPRS module Integra "M2106+" or "M2106B" a) SIM card insertion Danger! Ensure the mains voltage is disconnected before opening the FE260 housing, ensure it is not turned back on and verify that there is no voltage.
Connect a PC with enSuite installed to the EK280 optical interface using the connection cable. Start enSuite and set up the communication link to the EK280. (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) ...
Page 88
In the base configuration now displayed you can define time windows, during which data can be cyclically retrieved from the EK280 via the modem. Time windows 5 and 6 are reserved for EK280 operation with an FE260, and generally only time window 5 is used. Redundant time windows can be deactivated by setting the time window start and end to the same value.
In the base configuration now displayed you can define time windows, during which data can be cyclically retrieved from the EK280 via the modem. Time windows 5 and 6 are reserved for EK280 operation with an FE260, and generally only time window 5 is used. Redundant time windows can be deactivated by setting the time window start and end to the same value.
Page 90
The test time window only needs to be open if none of the time windows 5 to 6 is currently open. If the communication link to the EK280 via the optical interface is not set up, it must be created. (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) ...
GSM operation, as explained in chapter 7.3.4. Here the GPRS Modem in the EK280 functions as a TCP-Server and may be addressed by a TCP client that is listed in its retrieval software through a static IP address. To allocate a static IP to the modem during the setup of the GPRS session, they must (together with their GPRS provider) maintain a virtual private network (VPN) which must be enabled on the SIM used in the modem.
Page 92
In the base configuration now displayed you can define time windows, during which data can be cyclically retrieved from the EK280 via the modem. Time windows 5 and 6 are reserved for EK280 operation with an FE260, and generally only time window 5 is used. Redundant time windows can be deactivated by setting the time window start and end to the same value.
Page 93
ECM-GW120 instead of "WipSoft". This can happen, for example, if the FE260 has been previously used with an EK260 which is now being swapped for an EK280. Since it was not possible to store the VPN access data in the EK260, it could only be used for TCPserv applications with the modem application "ComTCPserv"!
Page 94
EK280 Application Manual Jumper "Mode" in Position "program" (lower position) Modem parameterization interface Connect a COM interface of your computer with the modem parameterization interface on the modem adapter board (see photograph) with the aid of a DSUB9-RS232 cable.
Page 95
"Extended". A dialog box opens for inputting the access data to the VPN: First, the name of your VPN (here "Elster-VPN, for example) will appear. Complete the remaining, initially empty fields with the access data for your VPN which you will obtain from your VPN administrator or from the GPRS network provider.
Page 96
Before starting a data transfer via the modem, you must ensure that there is adequate reception field strength. On the display of the EK280, move the cursor in the tab "Serv." to Interfaces >"Terminal interface. > GSM & GPRS > GSM.L ...
Page 97
The test time window only needs to be open if none of the time windows 5 to 6 is currently open. If the communication link to the EK280 via the optical interface is not set up, it must be created. (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) ...
7.3.6.3 Opening the customer lock In order for ComFTP to read data from the EK280 and save it on the server, at least one EK280 lock must be permanently open. For this purpose it is recommended to use the customer lock, as this contains the least write permissions and therefore avoids the risk of unauthorized parameter updates.
Page 99
In call windows 5 and 6 set start and end to the same value for each one and then select the "Transfer changes to device" icon at the top of the enSuite window. Then wait a minute, for any communications activity in progress on the EK280 to be safely stopped. b) Send parameter file ...
Page 100
EK280 Application Manual "ST3" configuration interface Jumper "Mode" in "program" with cable attached position Figure 14: Modem assembly with ECM-GW120 with "Mode" jumper and push-fitted parameterizing cable. Parameterizing interface "Mode" jumper Figure 15: Modem assembly with Integra M2106, "Mode" jumper and parameterization interface.
Page 101
Refit the "mode" jumper on the FE260 modem board in the "operation" position. 7.3.6.6 EK280 data transfer activation Set up a communication link via the optical interface between enSuite and the EK280 (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) again. ...
The SIM card is inserted and unlocked as described in chapter 7.3.2. 7.3.7.2 Parametrization of the EK280 For parameterization of the EK280 you will require a connection cable for the optical interface as well as the enSuite application, which can be downloaded for free at www.elster-instromet.com.
FE260! 7.3.8.1 Parameterization of the EK280 for operation with an FE260/Ethernet For parameterization of the EK280 you will require a connection cable for the optical interface as well as the enSuite application, which can be downloaded for free at www.elster-instromet.com.
Page 104
"Terminal interface." Setting time window for potential data retrievals Before the first opening of a time window, the FE260 must first be connected to the EK280 in accordance with Section 7.3.1 and must have been parameterized pursuant to Section 7.3.8.2! See Section 7.2.2.1, paragraph c) on page 69.
Page 105
EK280 Application Manual Wait for approx. 1 minute, so that the initialization string can be reliably sent from EK280 to the Ethernet card. Attention! Then it is necessary to perform a Reset of the Ethernet card (interrupt the ext. power supply to the FE260 briefly).
Connect a PC or laptop with enSuite installed to the EK280 optical interface using the connection cable. Start enSuite and set up the communication link to the EK280. (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15) ...
Page 107
In the base configuration now displayed you can define time windows, during which data can be cyclically retrieved from the EK280 via this interface. Time windows 5 and 6 are reserved for EK280 operation with an FE260, and generally only time window 5 is used. Redundant time windows can be deactivated by setting the time window start and end to the same value.
* In place of DTR you may use RTS (DB-9: Pin 7, DE-25: Pin 4). The signal must run continuously at positive voltage (high-signal) throughout the data transfer. RI may not be used! In EK280 battery operation the signal is switched off again (voltage ≤ 0 V, low signal), in order to preserve the EK280 battery's life.
Page 109
In the base configuration now displayed you can define time windows, during which data can be cyclically retrieved from the EK280 via the modem. Time windows 5 and 6 are reserved for EK280 operation with a direct RS232 connection, and generally only time window 5 is used. Redundant time windows can be deactivated by setting the time window start and end to the same value.
The MTL5051 is an approved "associated apparatus" and can therefore be used as an interface isolator, if the EK280 is installed in Zone 1. 7.4.2.1 Connection Explosion hazard! If EK280 operation takes place in a potentially explosive atmosphere, ensure that all safety instructions in the EK280 Operating Instructions are followed. 24 V = MTL5051...
Page 111
Connect a PC or laptop with enSuite installed to the EK280 optical interface using the connection cable. Start enSuite and set up the communication link to the EK280 (see chapter 3.1 "Setting up the communication link to the EK280 via optical interface", page 15). ...
Page 112
In the base configuration now displayed you can define time windows, during which data can be cyclically retrieved from the EK280 via the modem. Time windows 5 and 6 are reserved for EK280 operation with an MTL5051, and generally only time window 5 is used. Redundant time windows can be deactivated by setting the time window start and end to the same value.
7.4.3 RS485 interface, electrically isolated 7.4.3.1 Wiring When the EK280 is connected to a RS485 bus there must be no terminal resistors connected to the bus! Due to the current limit for intrinsically-safe apparatus approval, the EK280 cannot supply sufficient current to power terminal resistors.
Page 114
The position of the two jumpers on X5 means that the EK280 interface is electrically isolated from the rest of the circuit and therefore electromagnetic interference coupling is prevented.
In the base configuration now displayed you can define time windows, during which data can be cyclically retrieved from the EK280 via the RS485 bus. Time windows 5 and 6 are reserved for EK280 operation with a direct terminal interface connection, and generally only time window 5 is used. Redundant time windows can be deactivated by setting the time window start and end to the same value.
Page 116
EK280 Application Manual 7.4.4.1.1 Two-wire simplex - wiring This function is only available since EK280 software version 2.20. EK280 Data - Bus Master Data + RS485 Uext+ Power supply 8V (DC) Uext- Data - Further Data + Bus participants 7.4.4.1.2 Four-wire full duplex - wiring...
Page 117
7.4.4.3 EK280 Parameterization For parameterization of the EK280 you will require a connection cable for the optical interface as well as the enSuite application, which can be downloaded for free at www.elster-instromet.com. Follow the steps given in chapter 7.4.3.3, Parametrization of the EK280, page 112.
If the conditions for activating the time window connection are satisfied, then the interface is opened and the EK280 is ready to act as a recipient. If a modem is connected to this interface then the EK280 is only ready to act as a recipient after a further 30 seconds.
A point in time connection can be manually initiated at any time (e.g. for a test). To do so, change the parameter "TestC" to 1 ("open"). The EK280 opens the interface and attempts to reach the target. In order to follow the progress of the point in time connection, observe the "StCon" parameter and "SDst 1, 2".
Establishment of a connection has not yet started. The interface is activated specifically for the connection. The interface to be used for the connection (i.e. the modem) is busy, the EK280 will wait until connection can be established. Either the interface has just been used for another connection or the EK280 is waiting to try again after a failed connection attempt.
Disconnection from remote terminal in progress. Disconnection from remote terminal finished. Remote terminal not reached. Check the related EK280-phonebook entry or check the readiness for reception of the remote terminal. Remote terminal refused the connection. Check the related EK280-phonebook entry or check the readiness for reception of the remote terminal.
No additional hardware is needed for the application. The only requirements are the internal GSM/GPRS modem in the EK280 or a GSM/GPRS modem in the FE260. The application May be used with GSM or GPRS modems (however, GPRS data cannot be recorded).
Modem logged out, battery powered! The modem was unable to log on, as the external power supply failed! E.g. Maybe the EK280 is connected to the lighting system by mistake, so the power to the EK280 is switched off when the light is switched off.
EK280 Application Manual 8 Data transmission protocols 8.1 Modbus 8.1.1 Standard settings of the Modbus Map Following Modbus register assignment is factory-set: Register Short LIS200 Designation / value Format Unit Address Desc.. Address Bat.R Remaining battery life Months 2:404 Stat...
EK280 Application Manual 8.1.2 Formats Meanings of formats used: Format Description Format Description Ushort, 16 Bit Array6, BCD, 12 Bit Ulong, 32 Bit Array8, BCD, 16 Bit Counter6 IEEEfloat, 32 Bit Array2, BCD, 4 Bit Code Format Number of registers...
EK280 Application Manual 8.1.5 Modbus via RS232 interface In the EK280 communication via the terminal interface in RS232 operation can be via Modbus amongst others. Values can be read and updated and archives can be retrieved. 8.1.5.1 Connection RS232 interface connection is described in chapters 7.4.1.1 and 7.4.1.2 8.1.5.2 Parametrization of the EK280...
Table 4: Default connection parameters 8.1.6 Modbus via internal modem (Modbus RTU_TCP) In the EK280 communication via the internal GPRS modem in RTU_TCP mode can be via Modbus amongst others. Values can be read and updated and archives can be retrieved.
Page 128
EK280 Application Manual b) The "internal modem" interface, the Modbus parameters and the connection parameters for Modbus operation via internal modem are preset in this parameter file. c) Customized settings can be set using enSuite. To do this select "Navigation" on the left-hand side and then "Parameterize...
8.2 Operating a Modbus Master Modbus is a stateless single master protocol. Within the Modbus slave function of the EK280 (see Chapter 8.1) the master (retrieval system) can only retrieve the data from the terminal (slave) during an open time window.
EK280 Application Manual 8.2.2 Parameterization of Modbus master tasks It is established via the Modbus master task list which and how much data shall be read or written. This Modbus master task list, just like the standard Modbus table (see Chapter 8.1.1) contains a maximum of 70 entries (instances).
EK280 Application Manual Address Display Designation Meaning MBAdr "x" MMDir Modbus_Master_AdrDirec Data direction x:7C0 0: H-Wort first tion 1: L Word first MMTrM Modbus_Master_TransMo Transmission mode x:7C1 0: ASCII 1: RTU 2: RTU_TCP MMAdr Modbus_Master_SlaveAd Modbus slave address of x:7C2 Range: 0..247...
Page 132
Parameterization of the functions of the RS232 interface is described in Chapter 7.4.1.3. a) Send the parameter file for Modbus parameterization Send the following parameter file to the EK280 (see Chapter 3.6 Send parameter file): EK280_xvx. – RS-232 & Modbus-Master RTU (via connection 8 & ext. power supply) (*) The following Modbus parameters are preset in the file stated above: The first 24 tasks on the task list are processed.
Page 133
EK280 Application Manual Designation Modbus_Master_ Meaning Address Value Content TaskList_ … ...MdbStartAdr Modbus-Adr. 2:8C5 1:100Stat - Momentary status, total ...MdbNoReg Disp. 2:8C6 1 Register Register ...MdbRegRWMode RW-Mode 2:8C7 2: Write-FC06 ...MdbStartAdr Modbus-Adr. 3:8C5 4:302_2VmT - Total actual volume (post- decimal places) [10E-4 m3] ...MdbNoReg...
Parameterization of the functions of the internal modem is described in Chapter 7.1. a) Send the parameter file for Modbus parameterization Send the following parameter file to the EK280 (see Chapter 3.6 Send parameter file): EK280_xvx. - Modbus-Master RTU-TCP int.Modem Connection7 ext. Power supply (*) The following Modbus parameters are preset in this file: Link 7 is set up for Modbus master communications via the integrated modem.
Page 136
EK280 Application Manual Table 14: preprogrammed connection parameters for link 7 (RTU_TCP) The parameters of a link which produce the actual reference to the Modbus are the "Connection_ProtocolType" (states that the Modbus "shall be communicated with") and "Connection_ProtocolInfo" (contains the index regarding the Modbus master information which is relevant for this link).
If the internal GSM modem is connected (see chapter 7.1) or an external GSM modem respectively an external device including a GSM modem is connected to the serial interface, the EK280 is able to send SMS messages (Short Message Service of GSM-Providers) at occurrence of defined events.
Page 138
You can define up to 2 recipients per SMS message, with enSuite change to sub-menu "Interfaces" > "Telephone book" Choose free entries of the EK280 phone book and change to the related sub-menu: Telephone Definition book TelNo Phone number of the recipient including dialing code.
Page 139
Definition Event EK280 event, at occurrence the message will be transmitted. Within enSuite, press the button and select a status, a unique event or a regular event from the list shown. NoRcv 0 = no conn. (SMS is not active; will not be sent to any recipient)
EK280 Application Manual 9 Archive Changes to the flexible archive structures which were programmed as factory settings may lead to erroneous processing of read data in a subsequent system. In case of e.g. a power failure, no archived data is lost as all archives are stored in non-volatile memories.
In order to set the measurement period on the device to another value, open the administrator or calibration lock as described in the EK280 operating manual. If at least two entries are still free in the calibration manual then it is possible to change the measurement periods when the administrator lock is open.
9.1.6 Freeze metering period archive This function can be used to store a data row in the measurement period archive. Open the administrator lock as described in the EK280 operating manual. “Menu option 1: With This value is only displayed when the energy”...
EK280 Application Manual Move the cursor to "Serv." > "Archives" > "FrMP". Press the ENTER button "0" flashes. Change the value using the arrow buttons or to "1". Press the ENTER button to confirm the set value. It is possible to abort the entry by pressing the ESC button.
All values relating to daily limits can be created with the daily limit which can be set here. In order to set the daily limit on the device to another value, open the administrator lock as described in the EK280 operating manual. Move the cursor to "Serv."...
EK280 Application Manual To display the measured values relating to the daily limit, move the cursor to "Serv." > "Volume conversion" > "per day". Display Description K.Dyc Ø Mean value K of current day K.DyØ Mean value K of last day C.Dyc Ø...
EK280 Application Manual 9.3 Monthly archive 1 (Monthly meter readings) In monthly archive 1 meter readings and maximum consumption figures are archived on a monthly basis based on the monthly limit (= daily limit on the first day of each month) of the previous months.
EK280 Application Manual 9.3.4 Values relating to months 9.3.4.1 In the current month To display the volumes relating to the monthly limit, move the cursor to "Serv." > "Volume" > "current month". Display Description Maximum VbMP of current month VbMPc...
EK280 Application Manual 9.4 Monthly archive 2 (Measured values) In monthly archive 2 maximum, minimum and occasionally median values for Qb, Qm, p, T the previous months are archived on a monthly basis based on the monthly limit (= daily limit on the first day of each month).
EK280 Application Manual Pos. Address Display Description Retrievable 26:0161 C.Mo Mean value C of last month A + S 07:0110 St.7 Instance -Status 7 (incl. p) A + S 06:0110 St.6 Instance -Status 6 (incl. T) A + S 08:0110 St.8 Instance -Status 8 (incl.
EK280 Application Manual 9.4.4.2 In the previous month To display the measured values relating to the monthly limit, move the cursor to "Serv." > "Volume conversion" > "previous month". Display Description K.Mo Ø Mean value K of last month C.Mo Ø...
EK280 Application Manual 9.5.2 Memory capacity The archive can store the last 500 status changes. The manual is a ring-type memory. If the archive is full then the oldest entries are overwritten. 9.5.3 Deleting the manual See Chapter 2.4.2 Clear volumes and archives ("Clr.V").
The update archive is also deleted via the function "ClrV" (see Chapter 2.4.2 Clear volumes and archives ("Clr.V")). So that the updates archive is deleted from the device, open the calibration lock as described in the EK280 operating instructions. Move the cursor to "Serv."...
With the aid of the calibration data log, several parameters which are relevant from a statutory calibration viewpoint (see the EK280 operating instructions) can be changed when the administrator lock is open. A data row is entered for each alteration of such a parameter when the calibration lock is closed. In addition, an entry is always made when opening and closing the calibration lock.
ESC button. 9.9 User archive The EK280 has five user archives (archive 11, archive 12, archive 13, archive 14 and archive 15). The contents of the user archives can be shown on the display of the device via the path "Serv."...
Application Manual 10 Status messages The EK280 gives two types of status information: Momentary status "Stat" (also referred to as "status") and status register "SReg". These are located on the "Admin." and "Serv." display tabs under "Status". Messages in the "Stat" momentary status indicate current conditions such as pending errors. As soon as the condition is no longer present, the relevant message is removed from the momentary status.
Page 156
Please contact Elster support. b) Warnings: Dat.restaur. E The batteries of the EK280 are intermittently dropping out. As a result of this, the time has not changed and no measurement and volume conversion have happened. However, all data is available.
Page 157
The administrator / customer lock is open. Cust.lock o. Bat. operat. The EK280 is in battery mode. This signal is primarily used to inform a remote data transmission system that the batteries run down more quickly during long periods of data transmission.
Page 158
The specified call pickup time is active, i.e. the volume corrector will accept data transmission calls. Call Win.2 Call Win.3 Call Win.4 Call Win.5 Call Win.6 Anr.zeitp1 The specified call time is active, i.e., the EK280 makes a data transmission call to the remote terminal. Anr.zeitp2...
........approx. 5.0 years (readout duration 15 min/week) ........approx. 5.1 years (readout duration 1 min/day) 10.3.2 Encoder for volume measurement When using other parameter settings for the encoder (e.g. timings) in the EK280 then the battery life may become shorter. Conditions: Batteries: ......
EK280 Application Manual 10.3.3 Additional pressure or temperature sensors Conditions: Batteries: ......2 battery packs Mode input 1: ....NF pulse input (mode1) Communication: ....Data transfer via modem with "Ring" signal, i.e. internal GSM modem or an analog modem connected to terminals Outputs: ......
The battery capacity required by an isolated output for pulse output is determined by the EK280 and subtracted from the "BatRC" remaining battery life. However as the EK280 does not know how many pulses are to be output in the future, the predicted remaining battery life "Bat.R" is derived from the remaining battery life and calculated based on a default value.
EK280 Application Manual Not only the total duration, but also the number of time windows is relevant to battery life. So for example the battery life for a monthly 4 hour time window is differs from that for four time windows, each lasting 1 hour.
EK280 Application Manual 10.5 Data transfer duration in modem battery operation 10.5.1 Data transfer duration depending on ambient temperature In battery operation the modem battery power is reduced during data transfer. At a low ambient temperature it is reduced more quickly than at a high ambient temperature.