Power Connections For Three-Drawer Cabinet - Digital Equipment AlphaServer 4000 Configuration And Installation Manual

Hide thumbs Also See for AlphaServer 4000:
Table of Contents

Advertisement

The power controllers connect to an AC wall outlet. Each controller has a main
power switch and 10 outlets for system drawers, StorageWorks shelves, and fan tray.
When connecting system components to the controllers, note that system drawer
power cables are gray; StorageWorks shelf power cables and fan tray power cables
are gray. Configuration rules are:
A system drawer contains one to three power supplies; each power supply has
one power cable that connects to a power controller.
A StorageWorks shelf has one power cable; a shelf equipped with a redundant
power supply has two power cables.
Connect all system drawer power cables to the same AC power controller.
If a cabinet has three system drawers, connect the power cables as shown in
Figure 1–8.
Figure 1–8 Power Connections for Three-Drawer Cabinet
Power
Controller
Fantray
Power
Controller
Drawer 2
Drawer 3
StorageWorks
Drawer 1
StorageWorks
To Wall Outlets
PK0695-97
Configuration Rules
1-13