Standards Applied - METREL EurotestXC MI 3152 Instruction Manual

Eurotestxc eurotestxc 2,5 kv
Table of Contents

Advertisement

MI 3152(H) EurotestXC (2,5 kV)

Standards applied

1.4
The EurotestXC instruments are manufactured and tested in accordance with the following
regulations:
Electromagnetic compatibility (EMC)
EN 61326-1
Safety (LVD)
EN 61010-1
EN 61010-2-030
EN 61010-031
EN 61010-2-032
Functionality
EN 61557
DIN 5032
Reference standards for electrical installations and components
EN 61008
EN 61009
IEC 60364-4-41
BS 7671
AS/NZS 3017
Electrical equipment for measurement, control and laboratory
use – EMC requirements
Class B (Hand-held equipment used in controlled EM environments)
Safety requirements for electrical equipment for measurement, control and
laboratory use – Part 1: General requirements
Safety requirements for electrical equipment for measurement, control and
laboratory use – Part 2-030: Particular requirements for testing and
measuring circuits
Safety requirements for electrical equipment for measurement, control and
laboratory use – Part 031: Safety requirements for hand-held probe
assemblies for electrical measurement and test
Safety requirements for electrical equipment for measurement, control,
and laboratory use - Part 2-032: Particular requirements for hand-held and
hand-manipulated current sensors for electrical test and measurement
Electrical safety in low voltage distribution systems up to 1000 V
– Equipment for testing, measuring or monitoring of protective
1500 V
AC
measures
Part 1: General requirements
Part 2: Insulation resistance
Part 3: Loop resistance
Part 4: Resistance of earth connection and equipotential bonding
Part 5: Resistance to earth
Part 6: Residual current devices (RCDs) in TT and TN systems
Part 7: Phase sequence
Part 10: Combined measuring equipment
Part 12: Performance measuring and monitoring devices (PMD)
Photometry
Part 7: Classification of illuminance meters and luminance meters
Residual current operated circuit-breakers without integral overcurrent
protection for household and similar uses
Residual current operated circuit-breakers with integral overcurrent
protection for household and similar uses
Electrical installations of buildings Part 4-41 Protection for safety –
protection against electric shock
IEE Wiring Regulations (17
Electrical installations – Verification guidelines
th
edition)
15
General description
and
AC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eurotestxc mi 3152h

Table of Contents