Summary of Contents for METREL MI 3144 Euro Z 800 V

  • Page 1 MI 3144 Euro Z 800 V MI 3143 Euro Z 440 V Measuring instruments and testers www.metrel.si Measuring and Regulation Equipment Manufacturer Page 1...
  • Page 2: Main Features

    Most powerful Industrial Safety & Quality bundles MI 3144 Euro Z 800 V and MI 3143 Euro Z 440 V MI 3144 Euro Z 800 V or MAIN FEATURES MI 3144 MI 3143 MI 3143 Euro Z 440 V both High Precision 4-wire 300A Z Line and Z Loop Impedance Tester •...
  • Page 3: General Data

    Eurotest XD/XC, Multiservicer XD or Android App APPLICATIONS GENERAL DATA • Live Power Transformer High Precision 4-wire 300 A Z Line / Loop Impedance Testing • CAT IV 600 V (3000 m) safety category; • Partial Voltage Drops and Partial Clamp Current’s Path* Resistances •...
  • Page 4 Most powerful Industrial Safety & Quality bundle MI 3144 Euro Z 800 V and MI 3143 Euro Z 440 V Page 4...
  • Page 5: Measurement Functions

    High Current dR 300A loop and line MI 3144 Euro Z 800 V and MI 3143 Euro Z measurements with completely insulated 440 V are multi-function, battery (Li-ion) voltmeter with supported current clamps...
  • Page 6: Technical Specifications

    Most powerful Industrial Safety & Quality bundle Technical specifications MI 3144 and MI 3143* High Current Impedance [Z], ΔR, R Selective Z line mΩ, Z loop mΩ Measuring range according to EN61557-3: 12.0 mΩ ... 19.99 Ω Measurement principle Voltage / Current measurement (synchronous sampling) Loop/Line Impedance Measuring range Resolution...
  • Page 7 0 … 599 A 3 kA 0,06 kA … 5,99 kA 0,00 … 5,99 kA 0,01 kA * only MI 3144 Euro Z 800 V GENERAL DATA Battery power supply 7,2 V DC (4,4 Ah Li-ion) Operation conditions: Battery charging time...
  • Page 8 • Soft carrying bag • Jumbo case • Extension cable reel ** Metrel ES Manager can be downloaded free of charge from • Jumbo case mount Metrel Web server. ** Metrel ES Manager can be downloaded free of charge from Metrel Web server.
  • Page 9: Optional Accessories

    A 1530 G clamp • • P 1101 BASIC to PRO license • • 2 pcs key upgrade for Metrel ES Manager A 1660 Extension test leads • • A 1597 Human body • • on reel, 75 m, red, resistance probe green, 2.5 mm...
  • Page 10 Calculated HOT Factor with the measured of Ipsc min and Ipfc min represents unique solution for predicting the factor of reserve in MI 3144 Euro Z 800 V case of an error on overheated transformers. Itest Systems with neutral conductor L-N: (1.5 x R...
  • Page 11 Circuits, connected in parallel, fuses, switches and powerful loads do not influence the tested result. R1+R2+R3 MI 3144 Euro Z 800 V C1-C2 R1+R2 Itest 4 wire (Kelvin) Itest...
  • Page 12 R1+R2+R3 MI 3144 Euro Z 800 V R1+R2 Itest 4 wire (Kelvin) Itest E a r t h Live testing of loop Impedance of a 400 Hz AC 110 V Ground Power Supply Unit.
  • Page 13 The MI 3144 Euro Z 800 V portable test unit is capable of loading and testing live circuit Portability of the test system with good impedance without disconnection from the power source. protection for all weather situation. Memorization and periodic comparison of test results can predict the maintenance procedure, servicing and fast troubleshooting in case of malfunction.
  • Page 14 MI 3144 compares loaded and unloaded battery’s voltage. Measured and calculated values are compared to the reference. The batteries from DC 3 V up to DC 260 V can be evaluated. MI 3144 Euro Z 800 V Itest U unloaded U loaded ΔU...
  • Page 15 Application Note - 5 (MI 3144) Flex & Iron One-Clamp High Current dR 300A Grounding method for Lightning systems Lightning protection on buildings with faraday cages and metal shields connected to Conductive paths through the building must conductive construction of the building must be tested periodically to check the connections evenly dissipate power of the lightning from the lightning rods to the grounding nets.
  • Page 16 Application Note - 6 (MI 3144 and MI 3143*) High Current dR 300A Integrity of Grounding system with Flex and Iron One-Clamp method* Ground impedance and ground bonding measurements have to be performed, after Properly designed, installed, and maintained installation and periodically to verify the continuity of buried ground conductors and grounding grid eliminates the shock hazard connectors to the ground.
  • Page 17 Application Note - 7 (MI 3144) ELR (MRCD) trip-out Current and trip-out Time testing The MI 3144 Euro Z 800 V instrument supports testing of ELRs (MRCDs) without integral Note (acc.to IEC 60947-2 Annex M) current breaking devices and with separate sensing means.
  • Page 18 Application Note - 8 (MI 3144 and MI 3143) Earth Potentials by method of measuring Step, Touch and Transfer voltages Measuring step and touch voltages caused by injecting a known amount of current into the Actual magnitude of step, touch and ground system offers better assurance that the grid meets its design objectives.
  • Page 19 Touch Voltage calculation on the instrument screen can be selected from the list of parameters. Fault current in the equation is a manually inserted value of the predicted power of a lightning strike, e.g. 50 kA. Combined with the body simulator A 1597, the measurement will be scaled to the potential risk around lightning systems.
  • Page 20 METREL d.d. Measuring and Regulation Equipment Manufacturer Ljubljanska 77, SI-1354 Horjul, Slovenia T +386 (0)1 75 58 200, F +386 (0)1 75 49 226 metrel@metrel.si, www.metrel.si Note! Photographs in this catalogue may slightly differ from the instruments at the time of delivery.