4.1 Troubleshooting — KX-TDA100/KX-TDA200
Error Code
Error Message
391
Data Link
established
392
Clock master card
selected
393
LAN Carrier
detected
394
IP-GW Core Data
Link established
395
IP-GW
Gatekeeper Error
Cleared
396
IP-GW Run
510*
SMDR disconnect •
234
Installation Manual
PROBABLE CAUSE
Connection with PC
Phone/PC Console or
Voice Processing
System (DPT
Integration)
established or restored
Clock master card has
been changed to the
one indicated by the
sub code
IP-GW card connected
to the LAN
IP-GW Core Data Link
established
Connection to the
Gatekeeper is
recovered
IP-GW is started from a
remote maintenance
PC
RS-232C cable not
connected
Breaking of RS-232C
cable
Printer (terminal
equipment)
malfunction
SOLUTION
This information is logged when
connection with PC Phone/PC
Console or Voice Processing System
(DPT Integration) is established, and
does not indicate an error condition
that needs to be solved.
However, if this is logged frequently
(with "305 Data Link failure"), check the
connection as it may not be done
properly.
Check if the proper card is selected as
the new clock master card
This information is logged when
synchronisation of LAN is established
This information is logged when IP-GW
Core Data Link is recovered
This information is logged when
connection to the Gatekeeper is
recovered
This information is logged when IP-GW
is started from a remote maintenance
PC
Check the RS-232C cable
Check the terminal equipment