4.1 Troubleshooting — KX-TDA100/KX-TDA200
PROBLEM
•
PS becomes out of
range.
•
Cannot make calls using
the PS.
•
Noise is frequent while
using the PS.
•
Conversations
disconnect while using
the PS.
•
PS stays out of service
when the CS status is
changed from Out of
Service to In Service.
222
Installation Manual
PROBABLE CAUSE
•
CSIF card is not
working.
•
CS is not working.
•
Location of CS is not
good.
•
Access system of the
PS is not properly set.
•
Call handover is not
working.
•
PS is out of CS coverage
area.
•
It may take about 20 s
for CS to start up after
the status has been
changed to In Service.
SOLUTION
•
Install the CSIF card properly.
•
Make sure that the cable is connected
properly with correct pin assignments.
Also, make sure that the cable does not
make short circuits.
•
Switch all DIP switches off.
•
Locate the CS properly (refer to "2.8.5
Site Survey Using the KX-TCA255/KX-
TD7590" or "2.9.5 Site Survey" ).
•
Change the access system setting of
the PS to the appropriate system or
automatic.
•
Locate the CS properly (refer to "2.8.5
Site Survey Using the KX-TCA255/KX-
TD7590" or "2.9.5 Site Survey" ).
•
Wait until the CS starts up.