8.1 Troubleshooting — KX-TDA30
Error Code
Error Message
320
IP-GW H.323
Dummy Call Test
Error
321
IP-GW
Gatekeeper Error
322
IP-GW
Gatekeeper
Registration Error
323
IP-GW SDRAM
Failure
324
IP-GW DPRAM
Failure
325
IP-GW LAN Chip
Failure
326
IP-GW Stop
370
IP-GW Rebooted
by Maintenance
Console
371
IP-GW Rebooted •
391
Data Link
established
392
Clock master card
selected
393
LAN Carrier
detected
418
Installation Manual
PROBABLE CAUSE
Detection of IP-GW
H.323 Dummy Call
Test error
Detection of
Gatekeeper access
error
Gatekeeper
Registration is failed
Detection of IP-GW
SDRAM error
Detection of IP-GW
DPRAM error
Detection of IP-GW
LAN Tip failure
IP-GW is stopped from
a remote maintenance
PC
IP-GW is rebooted
from a remote
maintenance PC
Optional service card
malfunction: IP-GW
Connection with PC
Phone/PC Console or
Voice Processing
System (DPT
Integration)
established or restored
Clock master card has
been changed to the
one indicated by the
sub code
IP-GW card connected
to the LAN
SOLUTION
Replace the corresponding optional
service card
Collect the log data of IP-GW (refer to
the documentation for the IP-GW card)
Check the IP address setting of
Gatekeeper
Check whether the Gatekeeper is
connected to the network and work
properly
Check the route to the Gatekeeper
Check the Gatekeeper setting
Replace the corresponding optional
service card
Replace the corresponding optional
service card
Replace the corresponding optional
service card
Collect the log data of IP-GW (refer to
the documentation for the IP-GW card)
This information is logged when IP-GW
is stopped from a remote maintenance
PC
This information is logged when IP-GW
is rebooted from a remote
maintenance PC
Check whether the software version of
the IP-GW card is correct
This information is logged when
connection with PC Phone/PC
Console or Voice Processing System
(DPT Integration) is established, and
does not indicate an error condition
that needs to be solved.
However, if this is logged frequently
(with "305 Data Link failure"), check the
connection as it may not be done
properly.
Check if the proper card is selected as
the new clock master card
This information is logged when
synchronisation of LAN is established